Changes for page 3.4 Protections
Last modified by Admin on 2025/11/10 11:45
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -309,6 +309,35 @@ 309 309 If there is the "Cell count error", the **“Critical error” **is generated. 310 310 ))) 311 311 312 +=== Temperature sensor count === 313 + 314 +To change the protection parameters from the mismatch of the number of temperature sensors to the set value, select the "Protections → Temperature sensor count" section: 315 + 316 +[[image:1762773073782-768.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]] 317 + 318 +In this section: 319 + 320 +* Enable – a flag to enable the protection; 321 +* Number of cells – a number of temperature sensors connected to the BMS; 322 +* Delay before setting the error, millisecond; 323 +* Delay before clearing the error, second; 324 +* Lock – a flag to block the error until the device is restarted. 325 + 326 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 327 + 328 +Error generation conditions: 329 + 330 +* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time. 331 + 332 +Conditions for removing the error: 333 + 334 +* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time. 335 + 336 +(% class="box warningmessage" %) 337 +((( 338 +If there is the "T-sensor count error", the **“Critical error” **is generated**.** 339 +))) 340 + 312 312 === Short circuit === 313 313 314 314 The BMS Mini device implements a protection of power circuits (contactors, power wires) against overheating caused by the flow of high current for a long time.