Changes for page 3.4 Protections
Last modified by Admin on 2025/11/10 11:45
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -96,7 +96,7 @@ 96 96 * Enable – a flag to enable the protection; 97 97 * Minimum cell voltage, V; 98 98 * Tolerant cell voltage, V; 99 -* Check the open circuit voltage instead of the actual voltage – a flag to use theU,,ocv,, (correcteddue to current and cell resistance) cell voltage instead of measured value;99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 100 100 * Delay before setting the error, millisecond; 101 101 * Delay before clearing the error, second; 102 102 * Lock – a flag to block the error until the device is restarted. ... ... @@ -124,7 +124,7 @@ 124 124 * Enable – a flag to enable the protection; 125 125 * Maximum cell voltage, V; 126 126 * Tolerant cell voltage, V; 127 -* Check the open circuit voltage instead of the actual voltage – a flag to use theU,,ocv,, (correcteddue to current and cell resistance) cell voltage instead of measured value;127 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 128 128 * Delay before setting the error, millisecond; 129 129 * Delay before clearing the error, second; 130 130 * Lock – a flag to block the error until the device is restarted. ... ... @@ -139,33 +139,6 @@ 139 139 140 140 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 141 141 142 -=== Cell imbalance === 143 - 144 -The BMS Mini S device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error when imbalance is above estimated threshold. 145 - 146 -To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section: 147 - 148 -[[image:1762772978976-565.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]] 149 - 150 -In this section: 151 - 152 -* Enable – a flag to enable the protection; 153 -* Maximum cell imbalance, V; 154 -* Tolerant cell imbalance, V; 155 -* Delay before setting the error, millisecond; 156 -* Delay before clearing the error, second; 157 -* Lock – a flag to block the error until the device is restarted. 158 - 159 -As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 160 - 161 -Error generation conditions: 162 - 163 -* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time. 164 - 165 -Conditions for removing the error: 166 - 167 -* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time. 168 - 169 169 === Low temperature === 170 170 171 171 The BMS Mini device implements battery protection from too low temperature. ... ... @@ -547,11 +547,6 @@ 547 547 548 548 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 549 549 550 -(% class="box warningmessage" %) 551 -((( 552 -If there is the "Stuck contactor" error, the **“Critical error” **is generated. 553 -))) 554 - 555 555 === Contactor feedback === 556 556 557 557 The BMS Mini device can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, the feedback signal must be connected to corresponding contactor feedback pin on X1 header. ... ... @@ -571,11 +571,6 @@ 571 571 572 572 * a command for charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 573 573 574 -(% class="box warningmessage" %) 575 -((( 576 -If there is the "Contactor feedback" error, the **“Critical error” **is generated. 577 -))) 578 - 579 579 === Insulation === 580 580 581 581 The BMS Mini device can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. ... ... @@ -597,11 +597,6 @@ 597 597 598 598 Error is set if corresponding discrete input is set up and it receives logical zero. 599 599 600 -(% class="box warningmessage" %) 601 -((( 602 -If there is the "Insulation" error, the **“Critical error” **is generated. 603 -))) 604 - 605 605 === Critical error === 606 606 607 607 To change the critical error parameters, select the "Protections → Critical error" section: ... ... @@ -618,26 +618,3 @@ 618 618 The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 619 619 620 620 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 621 - 622 -=== General error === 623 - 624 -To change the general error parameters, select the "Protections → Critical error" section: 625 - 626 -[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 627 - 628 -In this section: 629 - 630 -* Enable – a flag to enable the protection; 631 -* Delay before setting the error, millisecond; 632 -* Delay before clearing the error, second; 633 -* Lock – a flag to block the error until the device is restarted; 634 -* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 635 - 636 -The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 637 - 638 -The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 639 - 640 -(% class="box warningmessage" %) 641 -((( 642 -The state of the “General error” can be assigned to a discrete output or to a power switch. 643 -)))
- 1762772949184-209.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.0 KB - Content
- 1762772978976-565.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.0 KB - Content