Changes for page 3.4 Protections
Last modified by Admin on 2025/11/10 11:45
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -139,6 +139,33 @@ 139 139 140 140 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 141 141 142 +=== Cell imbalance === 143 + 144 +The BMS Mini S device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error when imbalance is above estimated threshold. 145 + 146 +To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section: 147 + 148 +[[image:1762772978976-565.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]] 149 + 150 +In this section: 151 + 152 +* Enable – a flag to enable the protection; 153 +* Maximum cell imbalance, V; 154 +* Tolerant cell imbalance, V; 155 +* Delay before setting the error, millisecond; 156 +* Delay before clearing the error, second; 157 +* Lock – a flag to block the error until the device is restarted. 158 + 159 +As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 160 + 161 +Error generation conditions: 162 + 163 +* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time. 164 + 165 +Conditions for removing the error: 166 + 167 +* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time. 168 + 142 142 === Low temperature === 143 143 144 144 The BMS Mini device implements battery protection from too low temperature. ... ... @@ -282,6 +282,35 @@ 282 282 If there is the "Cell count error", the **“Critical error” **is generated. 283 283 ))) 284 284 312 +=== Temperature sensor count === 313 + 314 +To change the protection parameters from the mismatch of the number of temperature sensors to the set value, select the "Protections → Temperature sensor count" section: 315 + 316 +[[image:1762773073782-768.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]] 317 + 318 +In this section: 319 + 320 +* Enable – a flag to enable the protection; 321 +* Number of cells – a number of temperature sensors connected to the BMS; 322 +* Delay before setting the error, millisecond; 323 +* Delay before clearing the error, second; 324 +* Lock – a flag to block the error until the device is restarted. 325 + 326 +As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 327 + 328 +Error generation conditions: 329 + 330 +* the number of temperature sensors connected to the BMS is **not equal** to the “Number of temperature sensors” value during the “Delay before setting the error” time. 331 + 332 +Conditions for removing the error: 333 + 334 +* the number of temperature sensors connected to the BMS is **equal** to the “Number of temperature sensors” value during the “Delay before clearing the error” time. 335 + 336 +(% class="box warningmessage" %) 337 +((( 338 +If there is the "T-sensor count error", the **“Critical error” **is generated**.** 339 +))) 340 + 285 285 === Short circuit === 286 286 287 287 The BMS Mini device implements a protection of power circuits (contactors, power wires) against overheating caused by the flow of high current for a long time.
- 1762773073782-768.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.6 KB - Content