Changes for page 3.4 Protections

Last modified by Admin on 2025/11/10 11:45

From version 14.1
edited by Admin
on 2025/04/09 12:20
Change comment: There is no comment for this version
To version 18.1
edited by Admin
on 2025/11/10 11:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -96,7 +96,7 @@
96 96  * Enable – a flag to enable the protection;
97 97  * Minimum cell voltage, V;
98 98  * Tolerant cell voltage, V;
99 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
99 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage instead of measured value;
100 100  * Delay before setting the error, millisecond;
101 101  * Delay before clearing the error, second;
102 102  * Lock – a flag to block the error until the device is restarted.
... ... @@ -124,7 +124,7 @@
124 124  * Enable – a flag to enable the protection;
125 125  * Maximum cell voltage, V;
126 126  * Tolerant cell voltage, V;
127 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;
127 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage instead of measured value;
128 128  * Delay before setting the error, millisecond;
129 129  * Delay before clearing the error, second;
130 130  * Lock – a flag to block the error until the device is restarted.
... ... @@ -139,6 +139,33 @@
139 139  
140 140  * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time.
141 141  
142 +=== Cell imbalance ===
143 +
144 +The BMS Mini S device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error when imbalance is above estimated threshold.
145 +
146 +To change the battery protection parameters from cell imbalance, select the "Protections → Cell imbalance" section:
147 +
148 +[[image:1762772978976-565.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]]
149 +
150 +In this section:
151 +
152 +* Enable – a flag to enable the protection;
153 +* Maximum cell imbalance, V;
154 +* Tolerant cell imbalance, V;
155 +* Delay before setting the error, millisecond;
156 +* Delay before clearing the error, second;
157 +* Lock – a flag to block the error until the device is restarted.
158 +
159 +As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated.
160 +
161 +Error generation conditions:
162 +
163 +* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time.
164 +
165 +Conditions for removing the error:
166 +
167 +* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time.
168 +
142 142  === Low temperature ===
143 143  
144 144  The BMS Mini device implements battery protection from too low temperature.
1762772949184-209.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.0 KB
Content
1762772978976-565.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.0 KB
Content