Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -520,11 +520,6 @@ 520 520 521 521 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 522 522 523 -(% class="box warningmessage" %) 524 -((( 525 -If there is the "Stuck contactor" error, the **“Critical error” **is generated. 526 -))) 527 - 528 528 === Contactor feedback === 529 529 530 530 The BMS Mini device can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, the feedback signal must be connected to corresponding contactor feedback pin on X1 header. ... ... @@ -544,11 +544,6 @@ 544 544 545 545 * a command for charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 546 546 547 -(% class="box warningmessage" %) 548 -((( 549 -If there is the "Contactor feedback" error, the **“Critical error” **is generated. 550 -))) 551 - 552 552 === Insulation === 553 553 554 554 The BMS Mini device can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. ... ... @@ -570,11 +570,6 @@ 570 570 571 571 Error is set if corresponding discrete input is set up and it receives logical zero. 572 572 573 -(% class="box warningmessage" %) 574 -((( 575 -If there is the "Insulation" error, the **“Critical error” **is generated. 576 -))) 577 - 578 578 === Critical error === 579 579 580 580 To change the critical error parameters, select the "Protections → Critical error" section: ... ... @@ -591,23 +591,3 @@ 591 591 The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 592 592 593 593 The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 594 - 595 -=== General error === 596 - 597 -To change the general error parameters, select the "Protections → Critical error" section: 598 - 599 -[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 600 - 601 -In this section: 602 - 603 -* Enable – a flag to enable the protection; 604 -* Delay before setting the error, millisecond; 605 -* Delay before clearing the error, second; 606 -* Lock – a flag to block the error until the device is restarted; 607 -* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 608 - 609 -The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 610 - 611 -The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 612 - 613 -The state of the “General error” can be assigned to a discrete output or to a power switch.