Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:23

From version 11.1
edited by Admin
on 2025/02/26 12:46
Change comment: There is no comment for this version
To version 8.2
edited by Admin
on 2025/02/26 12:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -573,26 +573,21 @@
573 573  * Delay before clearing the error, second;
574 574  * Lock – a flag to block the error until the device is restarted.
575 575  
576 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
576 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time:
577 577  
578 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
578 +* “Battery cover error”;
579 +* “Cell monitor offline”;
580 +* “Cell count error”;
581 +* “ADC error”;
582 +* “Current sensor error”;
583 +* “Shunt offline”;
584 +* “Shunt error”;
585 +* “No temp. sensors”;
586 +* “Temp. sensor is shorted”;
587 +* “Settings error”;
588 +* “WDT reset”;
589 +* “Stuck contactor”;
590 +* “Contactor feedback error”;
591 +* “Insulation fault”.
579 579  
580 -=== General error ===
581 -
582 -To change the general error parameters, select the "Protections → Critical error" section:
583 -
584 -[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]
585 -
586 -In this section:
587 -
588 -* Enable – a flag to enable the protection;
589 -* Delay before setting the error, millisecond;
590 -* Delay before clearing the error, second;
591 -* Lock – a flag to block the error until the device is restarted;
592 -* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors.
593 -
594 -The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
595 -
596 -The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time.
597 -
598 -The state of the “General error” can be assigned to a discrete output or to a power switch.
593 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
1740573914327-561.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.6 KB
Content