Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -127,6 +127,7 @@ 127 127 * Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 128 128 * Delay before setting the error, millisecond; 129 129 * Delay before clearing the error, second; 130 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 130 130 * Lock – a flag to block the error until the device is restarted. 131 131 132 132 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -393,6 +393,7 @@ 393 393 * Delay before setting the error, millisecond; 394 394 * Delay before clearing the error, second; 395 395 * Lock – a flag to block the error until the device is restarted. 397 +* Number of cycles – a number of the charging contactor switchings made during battery operation. 396 396 397 397 If there is the high switching frequency of the charging contactor, the “CH contactor cycles error” is generated. 398 398 ... ... @@ -410,7 +410,7 @@ 410 410 411 411 To change the protection parameters against high frequency switching of the discharging contactor, select the "Protections → Discharging contactor cycles" section: 412 412 413 -[[image:17 40571600741-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="128" width="800"]]415 +[[image:1733748068420-615.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="139" width="800"]] 414 414 415 415 In this section: 416 416 ... ... @@ -420,6 +420,7 @@ 420 420 * Delay before setting the error, millisecond; 421 421 * Delay before clearing the error, second; 422 422 * Lock – a flag to block the error until the device is restarted. 425 +* Number of cycles – a number of the charging contactor switchings made during battery operation. 423 423 424 424 If there is the high switching frequency of the discharging contactor, the “DCH contactor cycles error” is generated. 425 425 ... ... @@ -545,15 +545,11 @@ 545 545 546 546 To change the insulation monitoring parameters, select the "Protections → Insulation" section: 547 547 548 -[[image:1740 573733492-485.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="800"]]551 +[[image:1733748083469-478.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 549 549 550 550 In this section: 551 551 552 552 * Enable – a flag to enable the protection; 553 -* Checking algorithm – isolation checking mode: 554 -** Always on – check is always performed; 555 -** On charging – check is performed only if “Charger connected” or “Charge request” is set; 556 -** Except charging - check is performed only if “Charger connected” and “Charge request” are cleared; 557 557 * Delay before setting the error, second; 558 558 * Delay before clearing the error, second; 559 559 * Lock – a flag to block the error until the device is restarted. ... ... @@ -573,26 +573,21 @@ 573 573 * Delay before clearing the error, second; 574 574 * Lock – a flag to block the error until the device is restarted. 575 575 576 -The "Critical error"signal is generated if at least one of thecritical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signalsanderrors.WebHome||anchor="HErrors"]])is generated during the “Delay before setting the error” time.575 +The critical error flag is generated if at least one of the following errors is generated during the “Delay before setting the error” time: 577 577 578 -The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 577 +* “Battery cover error”; 578 +* “Cell monitor offline”; 579 +* “Cell count error”; 580 +* “ADC error”; 581 +* “Current sensor error”; 582 +* “Shunt offline”; 583 +* “Shunt error”; 584 +* “No temp. sensors”; 585 +* “Temp. sensor is shorted”; 586 +* “Settings error”; 587 +* “WDT reset”; 588 +* “Stuck contactor”; 589 +* “Contactor feedback error”; 590 +* “Insulation fault”. 579 579 580 -=== General error === 581 - 582 -To change the general error parameters, select the "Protections → Critical error" section: 583 - 584 -[[image:1740573914327-561.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]] 585 - 586 -In this section: 587 - 588 -* Enable – a flag to enable the protection; 589 -* Delay before setting the error, millisecond; 590 -* Delay before clearing the error, second; 591 -* Lock – a flag to block the error until the device is restarted; 592 -* Errors 1, 2 to set the "Critical error" – bitfields to enable check of corresponding errors. 593 - 594 -The “General error” is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 595 - 596 -The “General error” is cleared if there are no errors from the enabled errors during the “Delay before clearing the error” time. 597 - 598 -The state of the “General error” can be assigned to a discrete output or to a power switch. 592 +The “Critical error” is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
- 1740571600741-802.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.6 KB - Content
- 1740573733492-485.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.4 KB - Content
- 1740573914327-561.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.6 KB - Content