Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -520,6 +520,11 @@ 520 520 521 521 * charging and discharging contactors are open, but the “Charging current present” or “Discharging current present” signal is set. 522 522 523 +(% class="box warningmessage" %) 524 +((( 525 +If there is the "Stuck contactor" error, the **“Critical error” **is generated. 526 +))) 527 + 523 523 === Contactor feedback === 524 524 525 525 The BMS Mini device can receive feedback signals from contactors and detect discrepancy between the control value and the feedback signal. To enable specific contactor protection, the feedback signal must be connected to corresponding contactor feedback pin on X1 header. ... ... @@ -539,6 +539,11 @@ 539 539 540 540 * a command for charging, precharge, discharging, charging/discharging or main contactor not matches its feedback value. 541 541 547 +(% class="box warningmessage" %) 548 +((( 549 +If there is the "Contactor feedback" error, the **“Critical error” **is generated. 550 +))) 551 + 542 542 === Insulation === 543 543 544 544 The BMS Mini device can detect a signal from an external insulation monitoring device (such as Bender IR155) to monitor the insulation quality. ... ... @@ -560,6 +560,11 @@ 560 560 561 561 Error is set if corresponding discrete input is set up and it receives logical zero. 562 562 573 +(% class="box warningmessage" %) 574 +((( 575 +If there is the "Insulation" error, the **“Critical error” **is generated. 576 +))) 577 + 563 563 === Critical error === 564 564 565 565 To change the critical error parameters, select the "Protections → Critical error" section: