Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -43,6 +43,46 @@ 43 43 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 44 44 * the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 45 45 46 +=== Charge current limit === 47 + 48 +The BMS Mini device can check if the charging current exceeds the estimated limit based on the [[Charge map>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HChargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 49 + 50 +Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 51 + 52 +To change the overcurrent protection of the battery, select the "Protections → Charge current limit" section: 53 + 54 +[[image:1740571132019-848.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="143" width="800"]] 55 + 56 +In this section: 57 + 58 +* Enable – a flag to enable the protection; 59 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 60 +* Region 1: Current difference – a value of maximum absolute current difference, A; 61 +* Region 2: Current difference – a value of maximum relative current excess, A; 62 +* Delay before setting the error, millisecond; 63 +* Delay before clearing the error, second; 64 +* Lock – a flag to block the error until the device is restarted. 65 + 66 +=== Discharge current limit === 67 + 68 +The BMS Mini device can check if the discharging current exceeds the estimated limit based on the [[Discharge map>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HDischargemap"]]. If current exceeds the calculated limit more than configured difference, "Current limit" error is generated. 69 + 70 +Current difference is separated to two regions by the threshold value. Maximum current in Region 1 is calculated by the absolute difference, in Region 2 – by the relative difference. 71 + 72 +To change the overcurrent protection of the battery, select the "Protections → Discharge current limit" section: 73 + 74 +[[image:1740571296344-411.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="151" width="800"]] 75 + 76 +In this section: 77 + 78 +* Enable – a flag to enable the protection; 79 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 80 +* Region 1: Current difference – a value of maximum absolute current difference, A; 81 +* Region 2: Current difference – a value of maximum relative current excess, A; 82 +* Delay before setting the error, millisecond; 83 +* Delay before clearing the error, second; 84 +* Lock – a flag to block the error until the device is restarted. 85 + 46 46 === Undervoltage === 47 47 48 48 The BMS Mini device implements battery protection from too low voltage on the cells. ... ... @@ -49,7 +49,7 @@ 49 49 50 50 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 51 51 52 -[[image:17 33748033237-837.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]92 +[[image:1740571345293-460.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 53 53 54 54 In this section: 55 55 ... ... @@ -56,6 +56,7 @@ 56 56 * Enable – a flag to enable the protection; 57 57 * Minimum cell voltage, V; 58 58 * Tolerant cell voltage, V; 99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 59 59 * Delay before setting the error, millisecond; 60 60 * Delay before clearing the error, second; 61 61 * Lock – a flag to block the error until the device is restarted. ... ... @@ -76,7 +76,7 @@ 76 76 77 77 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 78 78 79 -[[image:17 33748033238-995.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]120 +[[image:1740571383842-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="800"]] 80 80 81 81 In this section: 82 82 ... ... @@ -83,9 +83,9 @@ 83 83 * Enable – a flag to enable the protection; 84 84 * Maximum cell voltage, V; 85 85 * Tolerant cell voltage, V; 127 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 86 86 * Delay before setting the error, millisecond; 87 87 * Delay before clearing the error, second; 88 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 89 89 * Lock – a flag to block the error until the device is restarted. 90 90 91 91 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.
- 1740571132019-848.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.3 KB - Content
- 1740571296344-411.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.9 KB - Content
- 1740571345293-460.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.3 KB - Content
- 1740571383842-536.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content