Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:23

From version 1.5
edited by Admin
on 2025/02/24 14:08
Change comment: There is no comment for this version
To version 1.7
edited by Admin
on 2025/02/24 14:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -43,10 +43,6 @@
43 43  * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time;
44 44  * the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time.
45 45  
46 -(% class="box infomessage" %)
47 -(((
48 -If there is the "Overcurrent" error, the **charging **and **discharging **contactors open.
49 -)))
50 50  
51 51  === Undervoltage ===
52 52  
... ... @@ -75,10 +75,6 @@
75 75  
76 76  * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time.
77 77  
78 -(% class="box infomessage" %)
79 -(((
80 -If there is the "Undervoltage" error, the **discharging **contactor opens.
81 -)))
82 82  
83 83  === Overvoltage ===
84 84  
... ... @@ -108,11 +108,6 @@
108 108  
109 109  * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time.
110 110  
111 -(% class="box infomessage" %)
112 -(((
113 -If there is the "Overvoltage" error, the **charging **contactor and **discharging **contactor open (if the “Switch off the discharging contactor on error” flag is set).
114 -)))
115 -
116 116  === Low temperature ===
117 117  
118 118  The BMS Mini device implements battery protection from too low temperature.
... ... @@ -142,11 +142,6 @@
142 142  
143 143  * the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time.
144 144  
145 -(% class="box infomessage" %)
146 -(((
147 -If there is the "Low temperature (CH)" error, the **charging **contactor opens. If there is the "Low temperature (DCH)" error, the **discharging **contactor opens.
148 -)))
149 -
150 150  === High temperature ===
151 151  
152 152  The BMS Mini device implements battery protection from too high temperature.
... ... @@ -176,11 +176,6 @@
176 176  
177 177  * the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time.
178 178  
179 -(% class="box infomessage" %)
180 -(((
181 -If there is the "High temperature (CH)" error, the **charging **contactor opens. If there is the "High temperature (DCH)" error, the **discharging **contactor opens.
182 -)))
183 -
184 184  === Battery cover ===
185 185  
186 186  To change the protection parameters from opening the battery cover, select the "Protections → Battery cover" section:
... ... @@ -206,7 +206,7 @@
206 206  
207 207  (% class="box warningmessage" %)
208 208  (((
209 -If there is the "Battery cover error", the **“Critical error” **is generated **and all contactors open.**
186 +If there is the "Battery cover error", the **“Critical error” **is generated.
210 210  )))
211 211  
212 212  === Cell monitor offline ===
... ... @@ -234,7 +234,7 @@
234 234  
235 235  (% class="box warningmessage" %)
236 236  (((
237 -If there is the " Cell monitor offline error", the **“Critical error” **is generated and** all contactors open.**
214 +If there is the " Cell monitor offline error", the **“Critical error” **is generated.
238 238  )))
239 239  
240 240  === Cell count ===
... ... @@ -263,7 +263,7 @@
263 263  
264 264  (% class="box warningmessage" %)
265 265  (((
266 -If there is the "Cell count error", the **“Critical error” **is generated and **all contactors open.**
243 +If there is the "Cell count error", the **“Critical error” **is generated.
267 267  )))
268 268  
269 269  === Short circuit ===
... ... @@ -295,11 +295,6 @@
295 295  
296 296  * the current modulo is lower than the “Maximum current” values for all three protection levels during the “Delay before setting the error” time.
297 297  
298 -(% class="box infomessage" %)
299 -(((
300 -If there is the "Short circuit" error, the **charging **contactor opens (the “Switch off the charging contactor on error” flag is set) and the **discharging **contactor opens (the “Switch off the discharging contactor on error flag” is set).
301 -)))
302 -
303 303  === High contactor temperature ===
304 304  
305 305  The BMS Mini device protects power contactors from overheating. To measure the temperature of the contactor, one of the thermistors connected to the X6 connector is used.
... ... @@ -363,7 +363,7 @@
363 363  
364 364  (% class="box warningmessage" %)
365 365  (((
366 -If there is the “Current sensor error”, the **“Critical error” **is generated and** all contactors open.**
338 +If there is the “Current sensor error”, the **“Critical error” **is generated.
367 367  )))
368 368  
369 369  === Charge contactor cycles ===