Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:23
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,6 +6,12 @@ 6 6 7 7 The BMS Mini device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage. 8 8 9 +(% class="box errormessage" %) 10 +((( 11 +**Attention!** 12 +Behavior of contactors at different errors is configured in **corresponding contactor settings**! 13 +))) 14 + 9 9 === Overcurrent === 10 10 11 11 The BMS Mini device performs the overcurrent protection depending on current sensor values. ... ... @@ -37,10 +37,6 @@ 37 37 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 38 38 * the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 39 39 40 -(% class="box infomessage" %) 41 -((( 42 -If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 -))) 44 44 45 45 === Undervoltage === 46 46 ... ... @@ -69,10 +69,6 @@ 69 69 70 70 * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 71 71 72 -(% class="box infomessage" %) 73 -((( 74 -If there is the "Undervoltage" error, the **discharging **contactor opens. 75 -))) 76 76 77 77 === Overvoltage === 78 78 ... ... @@ -102,11 +102,6 @@ 102 102 103 103 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 104 104 105 -(% class="box infomessage" %) 106 -((( 107 -If there is the "Overvoltage" error, the **charging **contactor and **discharging **contactor open (if the “Switch off the discharging contactor on error” flag is set). 108 -))) 109 - 110 110 === Low temperature === 111 111 112 112 The BMS Mini device implements battery protection from too low temperature. ... ... @@ -136,11 +136,6 @@ 136 136 137 137 * the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 138 138 139 -(% class="box infomessage" %) 140 -((( 141 -If there is the "Low temperature (CH)" error, the **charging **contactor opens. If there is the "Low temperature (DCH)" error, the **discharging **contactor opens. 142 -))) 143 - 144 144 === High temperature === 145 145 146 146 The BMS Mini device implements battery protection from too high temperature. ... ... @@ -170,11 +170,6 @@ 170 170 171 171 * the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 172 172 173 -(% class="box infomessage" %) 174 -((( 175 -If there is the "High temperature (CH)" error, the **charging **contactor opens. If there is the "High temperature (DCH)" error, the **discharging **contactor opens. 176 -))) 177 - 178 178 === Battery cover === 179 179 180 180 To change the protection parameters from opening the battery cover, select the "Protections → Battery cover" section: ... ... @@ -200,7 +200,7 @@ 200 200 201 201 (% class="box warningmessage" %) 202 202 ((( 203 -If there is the "Battery cover error", the **“Critical error” **is generated **and all contactors open.**186 +If there is the "Battery cover error", the **“Critical error” **is generated. 204 204 ))) 205 205 206 206 === Cell monitor offline === ... ... @@ -228,7 +228,7 @@ 228 228 229 229 (% class="box warningmessage" %) 230 230 ((( 231 -If there is the " Cell monitor offline error", the **“Critical error” **is generated and** 214 +If there is the " Cell monitor offline error", the **“Critical error” **is generated and** all contactors open.** 232 232 ))) 233 233 234 234 === Cell count === ... ... @@ -357,7 +357,7 @@ 357 357 358 358 (% class="box warningmessage" %) 359 359 ((( 360 -If there is the “Current sensor error”, the **“Critical error” **is generated and** 343 +If there is the “Current sensor error”, the **“Critical error” **is generated and** all contactors open.** 361 361 ))) 362 362 363 363 === Charge contactor cycles ===