- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Mini SBMS Mini 2.3\. Configuration.WebHome1 +Battery management systems.BMS Mini S.3\. Configuration.WebHome - Content
-
... ... @@ -6,6 +6,12 @@ 6 6 7 7 The BMS Mini device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage. 8 8 9 +(% class="box errormessage" %) 10 +((( 11 +**Attention!** 12 +Behavior of contactors at different errors is configured in **corresponding contactor settings**! 13 +))) 14 + 9 9 === Overcurrent === 10 10 11 11 The BMS Mini device performs the overcurrent protection depending on current sensor values. ... ... @@ -37,10 +37,6 @@ 37 37 * the current is positive (charging) or zero, and its modulo value is less than the “Tolerant charging current” value for the “Delay before clearing the error” time; 38 38 * the current is negative (discharging), and its modulo value is less than the “Tolerant discharging current” value for the “Delay before clearing the error” time. 39 39 40 -(% class="box infomessage" %) 41 -((( 42 -If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 -))) 44 44 45 45 === Undervoltage === 46 46 ... ... @@ -69,10 +69,6 @@ 69 69 70 70 * the minimum voltage among all cells of the battery is greater than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 71 71 72 -(% class="box infomessage" %) 73 -((( 74 -If there is the "Undervoltage" error, the **discharging **contactor opens. 75 -))) 76 76 77 77 === Overvoltage === 78 78 ... ... @@ -102,11 +102,6 @@ 102 102 103 103 * the maximum voltage among all cells of the battery is less than the “Tolerant cell voltage” value for the “Delay before clearing the error” time. 104 104 105 -(% class="box infomessage" %) 106 -((( 107 -If there is the "Overvoltage" error, the **charging **contactor and **discharging **contactor open (if the “Switch off the discharging contactor on error” flag is set). 108 -))) 109 - 110 110 === Low temperature === 111 111 112 112 The BMS Mini device implements battery protection from too low temperature. ... ... @@ -136,11 +136,6 @@ 136 136 137 137 * the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 138 138 139 -(% class="box infomessage" %) 140 -((( 141 -If there is the "Low temperature (CH)" error, the **charging **contactor opens. If there is the "Low temperature (DCH)" error, the **discharging **contactor opens. 142 -))) 143 - 144 144 === High temperature === 145 145 146 146 The BMS Mini device implements battery protection from too high temperature. ... ... @@ -170,11 +170,6 @@ 170 170 171 171 * the maximum temperature among all cells of the battery is less than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 172 172 173 -(% class="box infomessage" %) 174 -((( 175 -If there is the "High temperature (CH)" error, the **charging **contactor opens. If there is the "High temperature (DCH)" error, the **discharging **contactor opens. 176 -))) 177 - 178 178 === Battery cover === 179 179 180 180 To change the protection parameters from opening the battery cover, select the "Protections → Battery cover" section: ... ... @@ -200,7 +200,7 @@ 200 200 201 201 (% class="box warningmessage" %) 202 202 ((( 203 -If there is the "Battery cover error", the **“Critical error” **is generated **and all contactors open.**186 +If there is the "Battery cover error", the **“Critical error” **is generated. 204 204 ))) 205 205 206 206 === Cell monitor offline === ... ... @@ -228,7 +228,7 @@ 228 228 229 229 (% class="box warningmessage" %) 230 230 ((( 231 -If there is the " Cell monitor offline error", the **“Critical error” **is generated and** all contactors open.**214 +If there is the " Cell monitor offline error", the **“Critical error” **is generated. 232 232 ))) 233 233 234 234 === Cell count === ... ... @@ -257,7 +257,7 @@ 257 257 258 258 (% class="box warningmessage" %) 259 259 ((( 260 -If there is the "Cell count error", the **“Critical error” **is generated and **all contactors open.**243 +If there is the "Cell count error", the **“Critical error” **is generated. 261 261 ))) 262 262 263 263 === Short circuit === ... ... @@ -289,11 +289,6 @@ 289 289 290 290 * the current modulo is lower than the “Maximum current” values for all three protection levels during the “Delay before setting the error” time. 291 291 292 -(% class="box infomessage" %) 293 -((( 294 -If there is the "Short circuit" error, the **charging **contactor opens (the “Switch off the charging contactor on error” flag is set) and the **discharging **contactor opens (the “Switch off the discharging contactor on error flag” is set). 295 -))) 296 - 297 297 === High contactor temperature === 298 298 299 299 The BMS Mini device protects power contactors from overheating. To measure the temperature of the contactor, one of the thermistors connected to the X6 connector is used. ... ... @@ -357,7 +357,7 @@ 357 357 358 358 (% class="box warningmessage" %) 359 359 ((( 360 -If there is the “Current sensor error”, the **“Critical error” **is generated and** all contactors open.**338 +If there is the “Current sensor error”, the **“Critical error” **is generated. 361 361 ))) 362 362 363 363 === Charge contactor cycles ===