Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/02/24 11:11

From version 4.2
edited by Admin
on 2025/02/24 10:53
Change comment: There is no comment for this version
To version 4.1
edited by Admin
on 2025/01/28 14:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,8 +12,19 @@
12 12  
13 13  [[image:1733743676787-110.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="173" width="800"]]
14 14  
15 -A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
15 +The device supports the following discrete inputs assignments:
16 16  
17 +* No input – input is not used;
18 +* Battery cover – a signal from the battery cover;
19 +* Charger connected – a signal indicating that charger is connected;
20 +* Power up/down request – a request to power down the device;
21 +* Inhibit charging – a command to open the charging contactor;
22 +* Inhibit discharging – a command to open the discharging contactor;
23 +* Insulation status – a signal from an insulation monitoring device;
24 +* Charge request – a request to close the charging contactor;
25 +* Precharge request – a request to close the precharging contactor;
26 +* Discharge request – a request to close the discharging contactor.
27 +
17 17  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
18 18  
19 19  [[image:1733743676791-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
... ... @@ -52,11 +52,6 @@
52 52  
53 53  The BMS Mini device has an ability to measure battery current via shunt sensor, connected to CAN bus.
54 54  
55 -(% class="box infomessage" %)
56 -(((
57 -**Note: **The shunt sensor communication protocol can be provided by request.
58 -)))
59 -
60 60  Shunt sensor settings are configured in the "Signals → Shunt sensor (CAN bus)" section:
61 61  
62 62  [[image:1733743676793-251.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
... ... @@ -88,8 +88,16 @@
88 88  
89 89  [[image:1733743676795-962.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
90 90  
91 -A list of available discrete output assignments is available in .
97 +The device supports the following digital output assignments:
92 92  
99 +* No output – output is not used.
100 +* Cooler – a command to turn on a cooler;
101 +* Heater – a command to turn on a heater;
102 +* Allow charging – a signal for a charger to start charging;
103 +* Precharging – a signal to charge the capacitive load;
104 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;
105 +* Power up – an indication of BMS power status.
106 +
93 93  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
94 94  
95 95  [[image:1733743676796-673.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]