Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/02/24 11:11
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,19 +12,8 @@ 12 12 13 13 [[image:1733743676787-110.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="173" width="800"]] 14 14 15 - Thedevice supportsthefollowingdiscrete inputsassignments:15 +A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 16 16 17 -* No input – input is not used; 18 -* Battery cover – a signal from the battery cover; 19 -* Charger connected – a signal indicating that charger is connected; 20 -* Power up/down request – a request to power down the device; 21 -* Inhibit charging – a command to open the charging contactor; 22 -* Inhibit discharging – a command to open the discharging contactor; 23 -* Insulation status – a signal from an insulation monitoring device; 24 -* Charge request – a request to close the charging contactor; 25 -* Precharge request – a request to close the precharging contactor; 26 -* Discharge request – a request to close the discharging contactor. 27 - 28 28 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 29 29 30 30 [[image:1733743676791-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]] ... ... @@ -63,6 +63,11 @@ 63 63 64 64 The BMS Mini device has an ability to measure battery current via shunt sensor, connected to CAN bus. 65 65 55 +(% class="box infomessage" %) 56 +((( 57 +**Note: **The shunt sensor communication protocol can be provided by request. 58 +))) 59 + 66 66 Shunt sensor settings are configured in the "Signals → Shunt sensor (CAN bus)" section: 67 67 68 68 [[image:1733743676793-251.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]] ... ... @@ -94,16 +94,8 @@ 94 94 95 95 [[image:1733743676795-962.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]] 96 96 97 - The devicesupportsthefollowing digital outputassignments:91 +A list of available discrete output assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 98 98 99 -* No output – output is not used. 100 -* Cooler – a command to turn on a cooler; 101 -* Heater – a command to turn on a heater; 102 -* Allow charging – a signal for a charger to start charging; 103 -* Precharging – a signal to charge the capacitive load; 104 -* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 105 -* Power up – an indication of BMS power status. 106 - 107 107 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 108 108 109 109 [[image:1733743676796-673.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]