Content
... ... @@ -12,19 +12,8 @@
12 12  
13 13  [[image:1733743676787-110.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="173" width="800"]]
14 14  
15 -The device supports the following discrete inputs assignments:
15 +A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
16 16  
17 -* No input – input is not used;
18 -* Battery cover – a signal from the battery cover;
19 -* Charger connected – a signal indicating that charger is connected;
20 -* Power up/down request – a request to power down the device;
21 -* Inhibit charging – a command to open the charging contactor;
22 -* Inhibit discharging – a command to open the discharging contactor;
23 -* Insulation status – a signal from an insulation monitoring device;
24 -* Charge request – a request to close the charging contactor;
25 -* Precharge request – a request to close the precharging contactor;
26 -* Discharge request – a request to close the discharging contactor.
27 -
28 28  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
29 29  
30 30  [[image:1733743676791-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
... ... @@ -63,6 +63,11 @@
63 63  
64 64  The BMS Mini device has an ability to measure battery current via shunt sensor, connected to CAN bus.
65 65  
55 +(% class="box infomessage" %)
56 +(((
57 +**Note: **The shunt sensor communication protocol can be provided by request.
58 +)))
59 +
66 66  Shunt sensor settings are configured in the "Signals → Shunt sensor (CAN bus)" section:
67 67  
68 68  [[image:1733743676793-251.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
... ... @@ -94,16 +94,8 @@
94 94  
95 95  [[image:1733743676795-962.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
96 96  
97 -The device supports the following digital output assignments:
91 +A list of available discrete output assignments is available in .
98 98  
99 -* No output – output is not used.
100 -* Cooler – a command to turn on a cooler;
101 -* Heater – a command to turn on a heater;
102 -* Allow charging – a signal for a charger to start charging;
103 -* Precharging – a signal to charge the capacitive load;
104 -* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;
105 -* Power up – an indication of BMS power status.
106 -
107 107  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
108 108  
109 109  [[image:1733743676796-673.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]]