Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/02/24 11:11
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,9 +74,8 @@ 74 74 * Invert – a flag to invert current values; 75 75 * Receive timeout – a timeout for receiving messages from BMS Current Sensor (if no data is being received from the current sensor during this time, the “Shunt offline” flag is set), millisecond; 76 76 * Mean value threshold – T,,M,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is between T,,M,, and T,,0,,, the BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, the BMS will use instantaneous value of current I,,I,,); 77 +* Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 77 77 78 -Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 79 - 80 80 === Temperature sensor === 81 81 82 82 Temperature sensors settings are configured in the "Signals → Temperature sensors" section: ... ... @@ -141,8 +141,14 @@ 141 141 142 142 === Wire resistance compensation === 143 143 144 -The BMS Mini is powered directly from the battery. This causes the voltages of the first and last battery cells to be measured with an error, the magnitude of which is proportional to the current drawn by the BMS and the resistance of the wires connecting these cells to the BMS. To compensate for the cell voltage measurement error, the BMS Mini provides a wire resistance setting. 143 +(% class="box warningmessage" %) 144 +((( 145 +**Warning!** 146 +This section applies only to **BMS Mini S v1.0 **and **BMS Mini v2.0 (device)**. 147 +))) 145 145 149 +The BMS Mini is powered directly from the battery. This causes the voltages of th fisrt and the last cells to be measured with an error, the magnitude of which is proportional to the current drawn by the BMS and the resistance of the wires connecting these cells to the BMS. To compensate for the cell voltage measurement error, the BMS Mini provides a wire resistance setting. 150 + 146 146 Setting the resistance of the wires connecting the first and last cells of the battery with the BMS is performed in the “Signals → Wire resistance compensation” section: 147 147 148 148 [[image:1733743676800-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]