Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/02/24 11:11
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Mini S.3\. Configuration.WebHome1 +Battery management systems.BMS Mini S.3\. Configuration.WebHome - Content
-
... ... @@ -74,9 +74,8 @@ 74 74 * Invert – a flag to invert current values; 75 75 * Receive timeout – a timeout for receiving messages from BMS Current Sensor (if no data is being received from the current sensor during this time, the “Shunt offline” flag is set), millisecond; 76 76 * Mean value threshold – T,,M,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is between T,,M,, and T,,0,,, the BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, the BMS will use instantaneous value of current I,,I,,); 77 +* Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 77 77 78 -Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 79 - 80 80 === Temperature sensor === 81 81 82 82 Temperature sensors settings are configured in the "Signals → Temperature sensors" section: