Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/02/24 11:11
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Mini S.3\. Configuration.WebHome1 +Battery management systems.BMS Mini S.3\. Configuration.WebHome - Content
-
... ... @@ -29,7 +29,6 @@ 29 29 30 30 [[image:1733743676791-123.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]] 31 31 32 - 33 33 === Current sensor === 34 34 35 35 The BMS Mini device has an ability to measure battery current by an external Hall-Effect current sensor. ... ... @@ -75,9 +75,8 @@ 75 75 * Invert – a flag to invert current values; 76 76 * Receive timeout – a timeout for receiving messages from BMS Current Sensor (if no data is being received from the current sensor during this time, the “Shunt offline” flag is set), millisecond; 77 77 * Mean value threshold – T,,M,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is between T,,M,, and T,,0,,, the BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, the BMS will use instantaneous value of current I,,I,,); 77 +* Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 78 78 79 -Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 80 - 81 81 === Temperature sensor === 82 82 83 83 Temperature sensors settings are configured in the "Signals → Temperature sensors" section: ... ... @@ -110,7 +110,6 @@ 110 110 111 111 [[image:1733743676796-673.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="169" width="800"]] 112 112 113 - 114 114 === MOSFETs === 115 115 116 116 The BMS Mini device has four MOSFET switches to drive contactors. For each switch, its assignment and inversion flag are set. ... ... @@ -141,7 +141,6 @@ 141 141 142 142 [[image:1733743676799-349.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="157" width="800"]] 143 143 144 - 145 145 === Wire resistance compensation === 146 146 147 147 The BMS Mini is powered directly from the battery. This causes the voltages of the first and last battery cells to be measured with an error, the magnitude of which is proportional to the current drawn by the BMS and the resistance of the wires connecting these cells to the BMS. To compensate for the cell voltage measurement error, the BMS Mini provides a wire resistance setting.