Changes for page 3.1 General information

Last modified by Admin on 2025/03/27 15:21

From version 8.1
edited by Admin
on 2024/12/26 17:37
Change comment: There is no comment for this version
To version 13.1
edited by Admin
on 2025/02/24 10:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,30 +4,37 @@
4 4  * CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported);
5 5  * TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3).
6 6  
7 -After connecting, the device is identified as a device with a serial interface (COM port) as in the figure below:
7 +To connect to the device, launch ElectricDeviceMonitor and select "Unified monitor" in the main program window.
8 8  
9 -[[image:1733743515976-982.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
9 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
10 10  
11 -To connect to the device, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window, specify the name of the device's COM port, and click the "Launch monitor" button:
11 + Choose the connection type and set up connection settings:
12 12  
13 -[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" height="340" width="450"]]
13 +* **Serial port (USB):** after connecting the USB cable, device will be identified as a device with a serial interface (COM port) as in the figure below:(((
14 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484262-545.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="311" width="450"]]
14 14  
15 - Choose the connection type and set up connection settings:
16 +In Unified monitor launcher window choose the corresponding COM port:
17 +)))
16 16  
17 -* Serial port (USB): choose the corresponding COM port;
19 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484267-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
18 18  
19 -[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484262-545.png||data-xwiki-image-style-alignment="center" height="311" width="450"]][[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484267-118.png||data-xwiki-image-style-alignment="center" height="248" width="450"]]
21 +* **Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN:** select the device in device list, specify the CAN speed and BMS device address:
20 20  
21 -* Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN: select the device in device list, specify the CAN speed and BMS device address:
23 +[[image:1735234432178-528.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
22 22  
23 -[[image:1735234432178-528.png||data-xwiki-image-style-alignment="center" height="248" width="450"]]
25 +* **TCP connection:** set up the device IP address.
24 24  
25 -* TCP connection: set up the device IP address.
27 +[[image:1735234420521-941.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
26 26  
27 -[[image:1735234420521-941.png||data-xwiki-image-style-alignment="center" height="248" width="450"]]
29 +When connected, the device asks for an access password.
28 28  
31 +Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu.
29 29  
30 -When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).
33 +|=User|=Default Password|=Description
34 +|Guest|guest|Guest access to view battery state. No permissions to change and view any settings
35 +|User|user|A common user access with permissions to change almost all the settings
36 +|Service|service|A service account for battery manufacturers. Has access to some additional settings
37 +|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others
31 31  
32 32  [[image:1733743515986-779.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="623" width="800"]]