... ... @@ -4,15 +4,13 @@
4 4  * CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported);
5 5  * TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3).
6 6  
7 -To connect to the device, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window, specify the name of the device's COM port, and click the "Launch monitor" button:
7 +To connect to the device, launch ElectricDeviceMonitor and select "Unified monitor" in the main program window.
8 8  
9 9  [[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
10 10  
11 11   Choose the connection type and set up connection settings:
12 12  
13 -* **Serial port (USB):**(((
14 -(% id="cke_bm_1235S" style="display:none" %) (%%)After connecting the USB cable, device will be identified as a device with a serial interface (COM port) as in the figure below:
15 -
13 +* **Serial port (USB):** after connecting the USB cable, device will be identified as a device with a serial interface (COM port) as in the figure below:(((
16 16  [[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484262-545.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="311" width="450"]]
17 17  
18 18  In Unified monitor launcher window choose the corresponding COM port:
... ... @@ -28,9 +28,16 @@
28 28  
29 29  [[image:1735234420521-941.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
30 30  
29 +When connected, the device asks for an access password.
31 31  
32 -When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).
31 +Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu.
33 33  
33 +|=User|=Default Password|=Description
34 +|Guest|guest|Guest access to view battery state. No permissions to change and view any settings
35 +|User|user|A common user access with permissions to change almost all the settings
36 +|Service|- (by request)|A service account for battery manufacturers. Has access to some additional settings
37 +|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others
38 +
34 34  [[image:1733743515986-779.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="623" width="800"]]
35 35  
36 36  After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":