1 -This document describes settings and states of the BMS Mini device. Configuration is carried out via the USB bus using the ElectricDeviceMonitor v1.17.3 or later (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]).
1 +Configuring can be done using the ElectricDeviceMonitor above the 1.17.3 (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) via
2 2  
3 -The USB-miniUSB cable (connector X2) is used to connect the BMS Mini device to a PC. After connecting, the device is identified as a device with a serial interface (COM port) as in the figure below:
3 +* USB;
4 +* CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported);
5 +* TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3).
4 4  
5 -[[image:1733743515976-982.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
7 +To connect to the device, launch ElectricDeviceMonitor and select "Unified monitor" in the main program window.
6 6  
7 -To connect to the device, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window, specify the name of the device's COM port, and click the "Launch monitor" button:
9 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
8 8  
9 -[[image:1733743515983-805.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
11 + Choose the connection type and set up connection settings:
10 10  
11 -[[image:1733743515985-471.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
13 +* **Serial port (USB):** after connecting the USB cable, device will be identified as a device with a serial interface (COM port) as in the figure below:(((
14 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484262-545.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="311" width="450"]]
12 12  
16 +In Unified monitor launcher window choose the corresponding COM port:
17 +)))
13 13  
14 -When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).
19 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484267-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
15 15  
21 +* **Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN:** select the device in device list, specify the CAN speed and BMS device address:
22 +
23 +[[image:1735234432178-528.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
24 +
25 +* **TCP connection:** set up the device IP address.
26 +
27 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1743088757725-539.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
28 +
29 +When connected, the device asks for an access password.
30 +
31 +Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu.
32 +
33 +|=User|=Default Password|=Description
34 +|Guest|guest|Guest access to view battery state. No permissions to change and view any settings
35 +|User|user|A common user access with permissions to change almost all the settings
36 +|Service|- (by request)|A service account for battery manufacturers. Has access to some additional settings
37 +|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others
38 +
16 16  [[image:1733743515986-779.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="623" width="800"]]
17 17  
18 18  After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":
1735234420521-941.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +14.2 KB
Content
1735234432178-528.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.4 KB
Content
1735234497008-519.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +34.0 KB
Content
1735234516873-750.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +34.5 KB
Content