Changes for page 3.1 General information
Last modified by Admin on 2025/03/27 15:21
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Mini S.3\. Configuration.WebHome1 +Battery management systems.BMS Mini S.3\. Configuration.WebHome - Content
-
... ... @@ -1,18 +1,41 @@ 1 - This document describes settings and states of the BMS Mini device.Configurationiscarriedout via theUSB bususing the ElectricDeviceMonitor v1.17.3or later(available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]).1 +Configuring can be done using the ElectricDeviceMonitor above the 1.17.3 (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) via 2 2 3 -The USB-miniUSB cable (connector X2) is used to connect the BMS Mini device to a PC. After connecting, the device is identified as a device with a serial interface (COM port) as in the figure below: 3 +* USB; 4 +* CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported); 5 +* TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main 3). 4 4 5 - [[image:1733743515976-982.png||data-xwiki-image-style-alignment="center"data-xwiki-image-style-border="true"]]7 +To connect to the device, launch ElectricDeviceMonitor and select "Unified monitor" in the main program window. 6 6 7 - To connecto thedevice, launch ElectricDeviceMonitor,select"Unifiedmonitor"inthemainprogramwindow, specifythenameofthe device'sCOM port, andclick theLaunchmonitor"button:9 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]] 8 8 9 - [[image:1733743515983-805.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]11 + Choose the connection type and set up connection settings: 10 10 11 -[[image:1733743515985-471.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] 13 +* **Serial port (USB):** after connecting the USB cable, device will be identified as a device with a serial interface (COM port) as in the figure below:((( 14 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484262-545.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="311" width="450"]] 12 12 16 +In Unified monitor launcher window choose the corresponding COM port: 17 +))) 13 13 14 - Whenconnected,thedeviceasksforaccess password.Forthe"User"account, the defaultpasswordis"user"(withoutquotes).19 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484267-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]] 15 15 21 +* **Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN:** select the device in device list, specify the CAN speed and BMS device address: 22 + 23 +[[image:1735234432178-528.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]] 24 + 25 +* **TCP connection:** set up the device IP address. 26 + 27 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1743088757725-539.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]] 28 + 29 +When connected, the device asks for an access password. 30 + 31 +Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu. 32 + 33 +|=User|=Default Password|=Description 34 +|Guest|guest|Guest access to view battery state. No permissions to change and view any settings 35 +|User|user|A common user access with permissions to change almost all the settings 36 +|Service|- (by request)|A service account for battery manufacturers. Has access to some additional settings 37 +|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others 38 + 16 16 [[image:1733743515986-779.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="623" width="800"]] 17 17 18 18 After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":
- 1735234420521-941.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.2 KB - Content
- 1735234432178-528.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.4 KB - Content
- 1735234497008-519.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.0 KB - Content
- 1735234516873-750.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +34.5 KB - Content