Wiki source code of 2. Installation and connection

Version 7.1 by Admin on 2025/02/06 11:41

Hide last authors
Admin 1.1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Installation and connection =
3
4 == Installation procedure ==
5
Admin 3.1 6 The mounting area of the BMS Mini S must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Mini S is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
Admin 1.1 7
8 The installation site must provide convenient access for subsequent connection to the device’s headers for connecting other system elements: a current sensor, contactors, display panels.
9
Admin 3.1 10 The BMS Mini S has a heat sink to dissipate the heat generated during the balancing of the cells. When used in enclosed enclosures, heat must be removed from the sink, otherwise it may damage the device.
Admin 1.1 11
Admin 3.1 12 Overall and mounting dimensions of the BMS Mini S are shown on figures below.
Admin 1.1 13
14
Admin 3.1 15 [[image:1733740731815-730.png||data-xwiki-image-style-alignment="center" height="454" width="516"]]
Admin 1.1 16
Admin 3.1 17 [[image:1733740731820-300.png||data-xwiki-image-style-alignment="center" height="172" width="453"]]
18
Admin 4.1 19 |**Parameter**|**Value **
20 |Overall dimensions (length × width × height), mm|124.5 × 117 × 17
Admin 3.1 21 |Mounting dimensions (length × width), mm|115 × 111
Admin 1.1 22 |Mounting holes|M3
Admin 7.1 23 |Headers X1, X3-X9 type|Molex series Micro-Fit
Admin 1.1 24
25 == Headers ==
26
Admin 3.1 27 There are names and locations of the BMS Mini S headers on figure below.
Admin 1.1 28
Admin 3.1 29 [[image:1733740765989-365.png||data-xwiki-image-style-alignment="center" height="423" width="526"]]
Admin 1.1 30
Admin 6.1 31 === X1 – header for contactors ===
Admin 1.1 32
33 [[image:1733738660904-795.jpeg||data-xwiki-image-style-alignment="center" height="96" width="316"]]
34
35 |**Pin**|**Name**|**Description**
36 |**1**|**-**|-
37 |**2**|**+12V**|Supply voltage from the internal 12V DC/DC converter
38 |**3**|**GND**|Ground
39 |**4**|**+12V**|Supply voltage from the internal 12V DC/DC converter
40 |**5**|**GND**|Ground
41 |**6**|**+12V**|Supply voltage from the internal 12V DC/DC converter
42 |**7**|**GND**|Ground
43 |**8**|**+12V**|Supply voltage from the internal 12V DC/DC converter
44 |**9**|**GND**|Ground
45 |**10**|**-**|-
46 |**11**|**FB1**|Feedback signal from contactor 1
47 |**12**|**OUT1**|Contactor control 1 (low side switch), 100V, max 5A
48 |**13**|**FB2**|Feedback signal from contactor 2
49 |**14**|**OUT2**|Contactor control 2 (low side switch), 100V, max 5A
50 |**15**|**FB3**|Feedback signal from contactor 3
51 |**16**|**OUT3**|Contactor control 3 (low side switch), 100V, max 5A
52 |**17**|**FB4**|Feedback signal from contactor 4
53 |**18**|**OUT4**|Contactor control 4 (low side switch), 100V, max 5A
54
55 (% class="box warningmessage" %)
56 (((
57 **ATTENTION!!!**
58 The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor:
Admin 4.1 59 [[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
Admin 1.1 60 )))
61
62 === X2 – mini-USB connector. ===
63
Admin 4.1 64 Mini-USB connector is used for configuring the BMS via ElectricDeviceMonitor.
Admin 1.1 65
Admin 3.1 66 === X3 – header for discrete inputs and outputs signals.[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]] ===
Admin 1.1 67
68 |**Pin**|**Name**|**Description**
69 |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V)
70 |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V)
71 |**3**|**DIN3**|Discrete input 3 “dry contact” (+5V)
72 |**4**|**DIN4**|Discrete input 4 “dry contact” (+5V)
73 |**5**|**DOUT1**|Discrete output 1 (+5V, 20mA)
74 |**6**|**DOUT2**|Discrete output 2 (+5V, 20mA)
75 |**7**|**DOUT3**|Discrete output 3 (+5V, 20mA)
76 |**8**|**DOUT4**|Discrete output 4 (+5V, 20mA)
77 |**9**|**GND**|Discrete input 1 “dry contact” (ground)
78 |**10**|**GND**|Discrete input 2 “dry contact” (ground)
79 |**11**|**GND**|Discrete input 3 “dry contact” (ground)
80 |**12**|**GND**|Discrete input 4 “dry contact” (ground)
81 |**13**|**GND**|Discrete output 1 (ground)
82 |**14**|**GND**|Discrete output 2 (ground)
83 |**15**|**GND**|Discrete output 3 (ground)
84 |**16**|**GND**|Discrete output 4 (ground)
85
86 === Х4 – header for САN and RS485 interfaces. ===
87
88 [[image:1733738660905-974.jpeg||data-xwiki-image-style-alignment="center" height="70" width="97"]]
89
90 |**Pin**|**Name**|**Description**
91 |**1**|**RS485_B**|RS485 line B
92 |**2**|**+5V**|Isolated supply voltage 5V, max 400mA
93 |**3**|**CAN_L**|CAN-L line of the CAN bus
94 |**4**|**RS485_A**|RS485 line A
95 |**5**|**GND**|Isolated ground
96 |**6**|**CAN_H**|CAN-H line of the CAN bus
97
Admin 3.1 98 === Х5 – header for ON/OFF button.[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]] ===
Admin 1.1 99
100 |**Pin**|**Name**|**Description**
101 |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V)
102 |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground)
103
104 === X6 – header for cells temperature sensors. ===
105
106 [[image:1733738660906-697.png||data-xwiki-image-style-alignment="center" height="91" width="190"]]
107
108 |**Pin**|**Name**|**Description**
109 |**1**|**TEMPG1**|Ground of the thermistor 1
110 |**2**|**TEMPG2**|Ground of the thermistor 2
111 |**3**|**TEMPG3**|Ground of the thermistor 3
112 |**4**|**TEMPG4**|Ground of the thermistor 4
113 |**5**|**TEMPG5**|Ground of the thermistor 5
114 |**6**|**TEMPG6**|Ground of the thermistor 6
115 |**7**|**TEMP1**|Signal from the thermistor 1
116 |**8**|**TEMP2**|Signal from the thermistor 2
117 |**9**|**TEMP3**|Signal from the thermistor 3
118 |**10**|**TEMP4**|Signal from the thermistor 4
119 |**11**|**TEMP5**|Signal from the thermistor 5
120 |**12**|**TEMP6**|Signal from the thermistor 6
121
Admin 3.1 122 === X7 - header for current sensor.[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] ===
Admin 1.1 123
124 |**Pin**|**Name**|**Description**
125 |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA
126 |**2**|**GND**|Ground
127 |**3**|**Vcs**|ADC input (current sensor output)
128 |**4**|**Vref**|Auxiliary ADC input (current sensor reference signal)
129
130 === Х8 – header for battery cells ===
131
Admin 3.1 132 [[image:1733740846257-439.png||data-xwiki-image-style-alignment="center" height="89" width="219"]]
Admin 1.1 133
134 |**Pin**|**Name**|**Description**
135 |**1**|**C0**|Minus of the cell stack (for measuring purposes only)
136 |**2**|**C2**|Cell 2
137 |**3**|**C4**|Cell 4
138 |**4**|**C6**|Cell 6
139 |**5**|**C8**|Cell 8
140 |**6**|**C10**|Cell 10
Admin 3.1 141 |**7**|**C12**|Cell 12 (maximum potential of the cell stack, for measuring purposes only)
142 |**8**|**NC**|Not connected
143 |**9**|**C1**|Cell 1 (minimum potential with respect to C0)
144 |**10**|**C3**|Cell 3
145 |**11**|**C5**|Cell 5
146 |**12**|**C7**|Cell 7
147 |**13**|**C9**|Cell 9
148 |**14**|**C11**|Cell 11
Admin 1.1 149
150 === Х9 – header to power the device ===
151
152 [[image:1733738660910-242.png||data-xwiki-image-style-alignment="center" height="61" width="78"]]
153
154 |**Pin**|**Name**|**Description**
Admin 3.1 155 |**1**|**VBAT+**|Supply voltage for BMS Mini S
156 |**2**|**VBAT-**|BMS Mini S power ground
Admin 1.1 157
158 (% class="box warningmessage" %)
159 (((
Admin 2.1 160 **Attention! **The BMS Mini S device is **galvanically connected** to the battery (the minus of the battery is the device ground). In view of this, when a BMS Wi-Fi or BMS GSM module is connected to the device, the antenna braid will also be galvanically connected to the battery (connected to the battery negative). It is recommended to** isolate the antenna cable from the battery case **to prevent negative potential from appearing on the case.
Admin 1.1 161 )))
162
163 === J1 – jumper for switching CAN bus terminal resistor ===
164
Admin 2.1 165 To connect the terminal resistor between the** CAN_H** and **CAN_L** lines, install the jumper J1 according to the following figure:
Admin 1.1 166
167 [[image:1733738660910-372.png||data-xwiki-image-style-alignment="center" height="85" width="162"]]
168
169 === J2 – jumper for switching RS-485 terminal resistor ===
170
Admin 2.1 171 To connect the terminal resistor between the** RS485_A** and **RS485_B** lines, install the jumper J1 according to the following figure:
Admin 1.1 172
173 [[image:1733738660910-372.png||data-xwiki-image-style-alignment="center" height="85" width="162"]]
174
175 == Connection procedure ==
176
177 === Connecting battery cells ===
178
179 To connect battery cells, follow figure below. Incorrect connection of the cells can damage the BMS Mini.
180
181 Begin the connection with the negative line of the battery: the “C0“ is connected to the “B-“, then the first cell (C1) is connected, then the second (С2), etc. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the most potential.
182
Admin 3.1 183 [[image:1733740980966-804.png||data-xwiki-image-style-alignment="center" height="471" width="721"]]
Admin 1.1 184
185 (% class="box warningmessage" %)
186 (((
187 **Attention!**
188 Connect the battery according to the diagram, otherwise the device may be damaged.
189 )))
190
191 === Connecting thermistors ===
192
193 Thermistors should be fastened to the cells, excluding short circuits to the cell terminals (for example, isolate thermistors with heat shrink).
194