1 | (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
2 | = Technical specifications = | ||
3 | |||
4 | BMS Mini S is a miniature full-featured centralized BMS for high-capacity lithium-ion batteries. It has many communication interfaces, an ability to collect information during the entire battery lifetime and an integrated DC/DC converter. | ||
5 | |||
6 | == Specifications == | ||
7 | |||
8 | (% style="width:624px" %) | ||
9 | |**Parameter**|(% style="width:230px" %)**Value** | ||
10 | |Battery voltage, V|10* to 52 | ||
11 | |((( | ||
12 | Current consumption @36 V, mA (maximum): | ||
13 | |||
14 | work (no load) | ||
15 | |||
16 | standby | ||
17 | )))|((( | ||
18 | |||
19 | |||
20 | 30 | ||
21 | |||
22 | 0.3 | ||
23 | ))) | ||
24 | |Number of cells|4 to 12 | ||
25 | |Cell balancing type|Passive | ||
26 | |Cell balancing current, mA, @ 4.2 V|220 | ||
27 | |Cell voltage measurement error, V|0.003 | ||
28 | |Cell temperature measurement error, °С|2 | ||
29 | |Output voltage of the internal DC/DC converter, V|12 ± 1 | ||
30 | |Output current of the internal DC/DC converter, A (maximum)|3 | ||
31 | |Number of programmable MOSFETs for contactors (100V, 5A)|4 | ||
32 | |Number of programmable discrete inputs (dry contact)|4 | ||
33 | |Number of programmable discrete outputs (5V, total 100mA)|4 | ||
34 | |Current sensor type|Hall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB) | ||
35 | |Interfaces|1xCAN / 1xRS-485 / 1xUSB | ||
36 | |CAN output voltage, V|5.0 ± 0.5 | ||
37 | |CAN output current, mA (maximum)|400 | ||
38 | |Additional modules|BMS Wi-Fi | ||
39 | |Dimensions (length × width × height), mm|125 × 117 × 17 | ||
40 | |Weight, g|210 ± 5 | ||
41 | |Operating temperature range, °С|-40 to +85 | ||
42 | |||
43 | * The minimum voltage for the internal 12V DC/DC converter is 14 Volts. | ||
44 | |||
45 | == Overall and mounting dimensions == | ||
46 | |||
47 | [[image:1733740566202-914.png||data-xwiki-image-style-alignment="center" height="158" width="451"]] | ||
48 | |||
49 | [[image:1733740566205-724.png||data-xwiki-image-style-alignment="center" height="449" width="496"]] | ||
50 | |||
51 | == Typical battery system == | ||
52 | |||
53 | Typical battery system based on the BMS Mini is shown on figure below. | ||
54 | |||
55 | [[image:1733740624419-743.png||data-xwiki-image-style-alignment="center"]] | ||
56 | |||
57 | == Safety rules == | ||
58 | |||
59 | The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances. | ||
60 | |||
61 | (% class="box errormessage" %) | ||
62 | ((( | ||
63 | **The system is not designed to work with batteries with total voltage more than 60 volts.** | ||