... ... @@ -28,7 +28,7 @@
28 28  |(% style="width:410px" %)Cell temperature measurement error, °С|(% style="width:225px" %)2
29 29  |(% style="width:410px" %)Output voltage of the internal DC/DC converter, V|(% style="width:225px" %)12 ± 1
30 30  |(% style="width:410px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:225px" %)3
31 -|(% style="width:410px" %)Number of programmable MOSFETs for contactors (60V, 5A)|(% style="width:225px" %)4
31 +|(% style="width:410px" %)Number of programmable MOSFETs for contactors (100V, 5A)|(% style="width:225px" %)4
32 32  |(% style="width:410px" %)Number of programmable discrete inputs (dry contact)|(% style="width:225px" %)4
33 33  |(% style="width:410px" %)Number of programmable discrete outputs (5V, total 100mA)|(% style="width:225px" %)4
34 34  |(% style="width:410px" %)Current sensor type|(% style="width:225px" %)Hall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB)
... ... @@ -54,4 +54,13 @@
54 54  
55 55  [[image:1733740624419-743.png||data-xwiki-image-style-alignment="center"]]
56 56  
57 +== Safety rules ==
58 +
59 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances.
60 +
61 +(% class="box errormessage" %)
62 +(((
63 +**The system is not designed to work with batteries with total voltage more than 60 volts.**
64 +)))