Changes for page 1. Technical specifications
Last modified by Admin on 2025/05/13 17:21
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,38 +7,38 @@ 7 7 8 8 == Specifications == 9 9 10 -(% style="width:64 0px" %)11 -|(% style="width:410px" %)**Parameter**|(% style="width:2 25px" %)**Value**12 -|(% style="width:410px" %)Battery voltage, V|(% style="width:2 25px" %)10* to 5210 +(% style="width:624px" %) 11 +|(% style="width:410px" %)**Parameter**|(% style="width:213px" %)**Value** 12 +|(% style="width:410px" %)Battery voltage, V|(% style="width:213px" %)10* to 52 13 13 |(% style="width:410px" %)((( 14 14 Current consumption @36 V, mA (maximum): 15 15 16 16 work (no load) 17 17 standby 18 -)))|(% style="width:2 25px" %)(((18 +)))|(% style="width:213px" %)((( 19 19 20 20 21 21 30 22 22 0.3 23 23 ))) 24 -|(% style="width:410px" %)Number of cells|(% style="width:2 25px" %)4 to 1225 -|(% style="width:410px" %)Cell balancing type|(% style="width:2 25px" %)Passive26 -|(% style="width:410px" %)Cell balancing current, mA, @ 4.2 V|(% style="width:2 25px" %)22027 -|(% style="width:410px" %)Cell voltage measurement error, V|(% style="width:2 25px" %)0.00328 -|(% style="width:410px" %)Cell temperature measurement error, °С|(% style="width:2 25px" %)229 -|(% style="width:410px" %)Output voltage of the internal DC/DC converter, V|(% style="width:2 25px" %)12 ± 130 -|(% style="width:410px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:2 25px" %)331 -|(% style="width:410px" %)Number of programmable MOSFETs for contactors ( 60V, 5A)|(% style="width:225px" %)432 -|(% style="width:410px" %)Number of programmable discrete inputs (dry contact)|(% style="width:2 25px" %)433 -|(% style="width:410px" %)Number of programmable discrete outputs (5V, total 100mA)|(% style="width:2 25px" %)434 -|(% style="width:410px" %)Current sensor type|(% style="width:2 25px" %)Hall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB)35 -|(% style="width:410px" %)Interfaces|(% style="width:2 25px" %)1xCAN / 1xRS-485 / 1xUSB36 -|(% style="width:410px" %)CAN output voltage, V|(% style="width:2 25px" %)5.0 ± 0.537 -|(% style="width:410px" %)CAN output current, mA (maximum)|(% style="width:2 25px" %)40038 -|(% style="width:410px" %)Dimensions (length × width × height), mm|(% style="width:2 25px" %)125 × 117 × 1739 -|(% style="width:410px" %)Weight, g|(% style="width:2 25px" %)210 ± 540 -|(% style="width:410px" %)Operating temperature range, °С|(% style="width:2 25px" %)-40 to +8541 -|(% style="width:410px" %)Headers X1, X3-X9 type|(% style="width:2 25px" %)Molex series Micro-Fit24 +|(% style="width:410px" %)Number of cells|(% style="width:213px" %)4 to 12 25 +|(% style="width:410px" %)Cell balancing type|(% style="width:213px" %)Passive 26 +|(% style="width:410px" %)Cell balancing current, mA, @ 4.2 V|(% style="width:213px" %)220 27 +|(% style="width:410px" %)Cell voltage measurement error, V|(% style="width:213px" %)0.003 28 +|(% style="width:410px" %)Cell temperature measurement error, °С|(% style="width:213px" %)2 29 +|(% style="width:410px" %)Output voltage of the internal DC/DC converter, V|(% style="width:213px" %)12 ± 1 30 +|(% style="width:410px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:213px" %)3 31 +|(% style="width:410px" %)Number of programmable MOSFETs for contactors (100V, 5A)|(% style="width:213px" %)4 32 +|(% style="width:410px" %)Number of programmable discrete inputs (dry contact)|(% style="width:213px" %)4 33 +|(% style="width:410px" %)Number of programmable discrete outputs (5V, total 100mA)|(% style="width:213px" %)4 34 +|(% style="width:410px" %)Current sensor type|(% style="width:213px" %)Hall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB) 35 +|(% style="width:410px" %)Interfaces|(% style="width:213px" %)1xCAN / 1xRS-485 / 1xUSB 36 +|(% style="width:410px" %)CAN output voltage, V|(% style="width:213px" %)5.0 ± 0.5 37 +|(% style="width:410px" %)CAN output current, mA (maximum)|(% style="width:213px" %)400 38 +|(% style="width:410px" %)Dimensions (length × width × height), mm|(% style="width:213px" %)125 × 117 × 17 39 +|(% style="width:410px" %)Weight, g|(% style="width:213px" %)210 ± 5 40 +|(% style="width:410px" %)Operating temperature range, °С|(% style="width:213px" %)-40 to +85 41 +|(% style="width:410px" %)Headers X1, X3-X9 type|(% style="width:213px" %)Molex series Micro-Fit 42 42 43 43 * The minimum voltage for the internal 12V DC/DC converter is 14 Volts. 44 44 ... ... @@ -54,4 +54,13 @@ 54 54 55 55 [[image:1733740624419-743.png||data-xwiki-image-style-alignment="center"]] 56 56 57 +== Safety rules == 58 + 59 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances. 60 + 61 +(% class="box errormessage" %) 62 +((( 63 +**The system is not designed to work with batteries with total voltage more than 60 volts.** 64 +))) 65 + 57 57