Last modified by Admin on 2025/05/13 17:21

From version 6.2
edited by Admin
on 2025/02/27 12:21
Change comment: There is no comment for this version
To version 7.1
edited by Admin
on 2025/02/27 12:24
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -8,37 +8,37 @@
8 8  == Specifications ==
9 9  
10 10  (% style="width:624px" %)
11 -|**Parameter**|(% style="width:230px" %)**Value**
12 -|Battery voltage, V|10* to 52
13 -|(((
11 +|(% style="width:410px" %)**Parameter**|(% style="width:213px" %)**Value**
12 +|(% style="width:410px" %)Battery voltage, V|(% style="width:213px" %)10* to 52
13 +|(% style="width:410px" %)(((
14 14  Current consumption @36 V, mA (maximum):
15 15  
16 16   work (no load)
17 17   standby
18 -)))|(((
18 +)))|(% style="width:213px" %)(((
19 19  
20 20  
21 21  30
22 22  0.3
23 23  )))
24 -|Number of cells|4 to 12
25 -|Cell balancing type|Passive
26 -|Cell balancing current, mA, @ 4.2 V|220
27 -|Cell voltage measurement error, V|0.003
28 -|Cell temperature measurement error, °С|2
29 -|Output voltage of the internal DC/DC converter, V|12 ± 1
30 -|Output current of the internal DC/DC converter, A (maximum)|3
31 -|Number of programmable MOSFETs for contactors (100V, 5A)|4
32 -|Number of programmable discrete inputs (dry contact)|4
33 -|Number of programmable discrete outputs (5V, total 100mA)|4
34 -|Current sensor type|Hall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB)
35 -|Interfaces|1xCAN / 1xRS-485 / 1xUSB
36 -|CAN output voltage, V|5.0 ± 0.5
37 -|CAN output current, mA (maximum)|400
38 -|Dimensions (length × width × height), mm|125 × 117 × 17
39 -|Weight, g|210 ± 5
40 -|Operating temperature range, °С|-40 to +85
41 -|Headers X1, X3-X9 type|Molex series Micro-Fit
24 +|(% style="width:410px" %)Number of cells|(% style="width:213px" %)4 to 12
25 +|(% style="width:410px" %)Cell balancing type|(% style="width:213px" %)Passive
26 +|(% style="width:410px" %)Cell balancing current, mA, @ 4.2 V|(% style="width:213px" %)220
27 +|(% style="width:410px" %)Cell voltage measurement error, V|(% style="width:213px" %)0.003
28 +|(% style="width:410px" %)Cell temperature measurement error, °С|(% style="width:213px" %)2
29 +|(% style="width:410px" %)Output voltage of the internal DC/DC converter, V|(% style="width:213px" %)12 ± 1
30 +|(% style="width:410px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:213px" %)3
31 +|(% style="width:410px" %)Number of programmable MOSFETs for contactors (100V, 5A)|(% style="width:213px" %)4
32 +|(% style="width:410px" %)Number of programmable discrete inputs (dry contact)|(% style="width:213px" %)4
33 +|(% style="width:410px" %)Number of programmable discrete outputs (5V, total 100mA)|(% style="width:213px" %)4
34 +|(% style="width:410px" %)Current sensor type|(% style="width:213px" %)Hall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB)
35 +|(% style="width:410px" %)Interfaces|(% style="width:213px" %)1xCAN / 1xRS-485 / 1xUSB
36 +|(% style="width:410px" %)CAN output voltage, V|(% style="width:213px" %)5.0 ± 0.5
37 +|(% style="width:410px" %)CAN output current, mA (maximum)|(% style="width:213px" %)400
38 +|(% style="width:410px" %)Dimensions (length × width × height), mm|(% style="width:213px" %)125 × 117 × 17
39 +|(% style="width:410px" %)Weight, g|(% style="width:213px" %)210 ± 5
40 +|(% style="width:410px" %)Operating temperature range, °С|(% style="width:213px" %)-40 to +85
41 +|(% style="width:410px" %)Headers X1, X3-X9 type|(% style="width:213px" %)Molex series Micro-Fit
42 42  
43 43  * The minimum voltage for the internal 12V DC/DC converter is 14 Volts.
44 44