... ... @@ -7,38 +7,41 @@
7 7  
8 8  == Specifications ==
9 9  
10 -(% style="width:640px" %)
11 -|(% style="width:410px" %)**Parameter**|(% style="width:225px" %)**Value**
12 -|(% style="width:410px" %)Battery voltage, V|(% style="width:225px" %)11* to 52
13 -|(% style="width:410px" %)(((
10 +(% style="width:624px" %)
11 +|**Parameter**|(% style="width:230px" %)**Value**
12 +|Battery voltage, V|10* to 52
13 +|(((
14 14  Current consumption @36 V, mA (maximum):
15 15  
16 16   work (no load)
17 +
17 17   standby
18 -)))|(% style="width:225px" %)(((
19 +)))|(((
19 19  
20 20  
21 21  30
23 +
22 22  0.3
23 23  )))
24 -|(% style="width:410px" %)Number of cells|(% style="width:225px" %)4 to 12
25 -|(% style="width:410px" %)Cell balancing type|(% style="width:225px" %)Passive
26 -|(% style="width:410px" %)Cell balancing current, mA, @ 4.2 V|(% style="width:225px" %)220
27 -|(% style="width:410px" %)Cell voltage measurement error, V|(% style="width:225px" %)0.003
28 -|(% style="width:410px" %)Cell temperature measurement error, °С|(% style="width:225px" %)2
29 -|(% style="width:410px" %)Output voltage of the internal DC/DC converter, V|(% style="width:225px" %)12 ± 1
30 -|(% style="width:410px" %)Output current of the internal DC/DC converter, A (maximum)|(% style="width:225px" %)3
31 -|(% style="width:410px" %)Number of programmable MOSFETs for contactors (60V, 5A)|(% style="width:225px" %)4
32 -|(% style="width:410px" %)Number of programmable discrete inputs (dry contact)|(% style="width:225px" %)4
33 -|(% style="width:410px" %)Number of programmable discrete outputs (5V, total 100mA)|(% style="width:225px" %)4
34 -|(% style="width:410px" %)Current sensor type|(% style="width:225px" %)Hall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB)
35 -|(% style="width:410px" %)Interfaces|(% style="width:225px" %)1xCAN / 1xRS-485 / 1xUSB
36 -|(% style="width:410px" %)CAN output voltage, V|(% style="width:225px" %)5.0 ± 0.5
37 -|(% style="width:410px" %)CAN output current, mA (maximum)|(% style="width:225px" %)400
38 -|(% style="width:410px" %)Dimensions (length × width × height), mm|(% style="width:225px" %)125 × 117 × 17
39 -|(% style="width:410px" %)Weight, g|(% style="width:225px" %)210 ± 5
40 -|(% style="width:410px" %)Operating temperature range, °С|(% style="width:225px" %)-40 to +85
41 -|(% style="width:410px" %)Headers X1, X3-X9 type|(% style="width:225px" %)Molex series Micro-Fit
26 +|Number of cells|4 to 12
27 +|Cell balancing type|Passive
28 +|Cell balancing current, mA, @ 4.2 V|220
29 +|Cell voltage measurement error, V|0.003
30 +|Cell temperature measurement error, °С|2
31 +|Output voltage of the internal DC/DC converter, V|12 ± 1
32 +|Output current of the internal DC/DC converter, A (maximum)|3
33 +|Number of programmable MOSFETs for contactors (100V, 5A)|4
34 +|Number of programmable discrete inputs (dry contact)|4
35 +|Number of programmable discrete outputs (5V, total 100mA)|4
36 +|Current sensor type|Hall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB)
37 +|Interfaces|1xCAN / 1xRS-485 / 1xUSB
38 +|CAN output voltage, V|5.0 ± 0.5
39 +|CAN output current, mA (maximum)|400
40 +|Additional modules|BMS Wi-Fi
41 +|Dimensions (length × width × height), mm|125 × 117 × 17
42 +|Weight, g|210 ± 5
43 +|Operating temperature range, °С|-40 to +85
44 +|Headers X1, X3-X9 type|Molex series Micro-Fit
42 42  
43 43  * The minimum voltage for the internal 12V DC/DC converter is 14 Volts.
44 44  
... ... @@ -54,4 +54,13 @@
54 54  
55 55  [[image:1733740624419-743.png||data-xwiki-image-style-alignment="center"]]
56 56  
60 +== Safety rules ==
61 +
62 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools, and appliances.
63 +
64 +(% class="box errormessage" %)
65 +(((
66 +**The system is not designed to work with batteries with total voltage more than 60 volts.**