Changes for page 3.6 Connectivity

Last modified by Admin on 2025/06/11 15:58

From version 4.1
edited by Admin
on 2025/03/03 10:20
Change comment: Загрузить новое вложение 1740997252420-589.png
To version 9.1
edited by Admin
on 2025/06/11 15:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,6 +6,10 @@
6 6  
7 7  === CAN (external) ===
8 8  
9 +The CAN1 (external) bus is used to configure the device and communicate with external devices (vehicle controller, inverter, display panel, etc.).
10 +
11 +Also CAN1 can be used as entry point to update child BMS Main 2.1 and BMS Mini controllers in battery modules.
12 +
9 9  To change the parameters of the external CAN bus, designed to configure the device and interact with the upper-level system, select the "Connectivity - CAN (external)" section:
10 10  
11 11  [[image:1740997082721-253.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="219" width="800"]]
... ... @@ -32,9 +32,9 @@
32 32  
33 33  === CAN (internal) ===
34 34  
35 -To change the parameters of the internal CAN bus designed to interact with battery modules based on BMS Main 2.x or BMS Mini S / BMS Mini 2, select the "Connectivity - CAN (internal)" section:
39 +To change the parameters of the internal CAN bus designed to interact with battery modules based on BMS Main 2.x or BMS Mini S / BMS Mini, select the "Connectivity - CAN (internal)" section:
36 36  
37 -[[image:1740997142807-180.png]]
41 +[[image:1740997142807-180.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
38 38  
39 39  In this section:
40 40  
... ... @@ -52,7 +52,7 @@
52 52  
53 53  To change the parameters for connecting to the RS-485 bus, select the “Connectivity – Modbus (RS-485)” section:
54 54  
55 -[[image:1734357425065-445.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="82" width="600"]]
59 +[[image:1740997252420-589.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="134" width="800"]]
56 56  
57 57  In this section:
58 58  
... ... @@ -71,8 +71,9 @@
71 71  
72 72  To change the settings for connecting to a Wi-Fi network, select the "Connectivity - Wi-Fi" section:
73 73  
74 -[[image:1734357425065-900.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="600"]]
78 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome@1733331899785-399.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]]
75 75  
80 +
76 76  In this section:
77 77  
78 78  * Enable – a flag to enable connection to a Wi-Fi network;
... ... @@ -79,3 +79,61 @@
79 79  * SSID – a name of the Wi-Fi network;
80 80  * Password – a password to connect to the Wi-Fi network;
81 81  * Security type – a secure connection type.
87 +
88 +(% class="box infomessage" %)
89 +(((
90 +To apply new settings please restart the BMS Main X.
91 +)))
92 +
93 +=== Cellular ===
94 +
95 +The BMS Main X device can connect to a cellular network if the BMS GSM communication module is installed on the device.
96 +
97 +To change the settings for connecting to a cellular network, select the "Connectivity → Cellular" section:
98 +
99 +[[image:1749656553248-551.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="800"]]
100 +
101 +In this section:
102 +
103 +* Enable – a flag to enable connection to a cellular network;
104 +* Module – version of BMS GSM module:
105 +** V1 (SIM7070G);
106 +* Network type:
107 +** GSM;
108 +** LTE CAT-M1;
109 +** LTE NB-IoT;
110 +* Use APN – a flag to enable APN;
111 +* APN: Name;
112 +* APN: User;
113 +* APN: Password;
114 +* Use PIN – a flag to enable the PIN code;
115 +* PIN number;
116 +
117 +(% class="box infomessage" %)
118 +(((
119 +To apply new settings please restart the BMS Main X device.
120 +)))
121 +
122 +=== LAN ===
123 +
124 +The BMS Main X device can connect to a local area network if the BMS LANmodule communication module is installed on the device.
125 +
126 +To change the settings for connecting to LAN, select the "Connectivity → LAN" section:
127 +
128 +[[image:Battery management systems.BMS Main 3.3\. Configuration.3\.6 Connectivity.WebHome@1733331899788-489.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="800"]]In this section:
129 +
130 +* Enable – a flag to enable connection to a local network;
131 +* Module – version of BMS LANmodule:
132 +** V1 (W5500);
133 +* MAC – a MAC address of LANmodule;
134 +* IP mode – a type of IP address:
135 +** Static – IP address is configured manually;
136 +** Dynamic – IP address is received from DHCP server;
137 +* IP address – IP address (in static IP mode);
138 +* Netmask – subnet mask (in static IP mode);
139 +* Gateway address – address of a gateway (in static IP mode).
140 +
141 +(% class="box infomessage" %)
142 +(((
143 +To apply new settings please restart the BMS Main X device.
144 +)))
1749656553248-551.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.0 KB
Content