... ... @@ -51,7 +51,7 @@ 51 51 52 52 To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → ATIB charger" section: 53 53 54 -[[image:1740996520416-882.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="800"]]54 +[[image:1740996520416-882.png]] 55 55 56 56 In this section: 57 57 ... ... @@ -65,18 +65,3 @@ 65 65 ((( 66 66 After changing the settings, restart the BMS Main X device. 67 67 ))) 68 - 69 -=== BMS IMD === 70 - 71 -To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section: 72 - 73 -[[image:1740996567134-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]] 74 - 75 -In this section: 76 - 77 -* Enable – a flag to enable communication with the IMD; 78 -* Node ID – a CANopen address of the BMS IMD device; 79 -* Configure IMD – a flag to override the IMD warning and alarm settings; 80 -* Allow work if battery modules are joined – a flag to allow the BMS IMD to work only if battery modules are joined; 81 -* Alarm threshold – a threshold resistance value to set insulation alarm, Ohm; 82 -* Warning threshold – a threshold resistance value to set insulation warning, Ohm.