50 50  === ATIB charger ===
51 51  
52 52  To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → ATIB charger" section:
53 -
54 -[[image:1740996520416-882.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="800"]]
55 -
56 -In this section:
57 -
58 -* Enable – a flag to enable communication with the charger;
59 -* Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
60 -* Output period - a period of sending commands to the charger, millisecond;
61 -* Charging voltage – maximum charging voltage, V;
62 -* Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
63 -
64 -(% class="box infomessage" %)
65 -(((
66 -After changing the settings, restart the BMS Main X device.
67 -)))
68 -
69 -=== BMS IMD ===
70 -
71 -To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section:
72 -
73 -[[image:1740996567134-294.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]
74 -
75 -In this section:
76 -
77 -* Enable – a flag to enable communication with the IMD;
78 -* Node ID – a CANopen address of the BMS IMD device;
79 -* Configure IMD – a flag to override the IMD warning and alarm settings;
80 -* Allow work if battery modules are joined – a flag to allow the BMS IMD to work only if battery modules are joined;
81 -* Alarm threshold – a threshold resistance value to set insulation alarm, Ohm;
82 -* Warning threshold – a threshold resistance value to set insulation warning, Ohm.