Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -215,7 +215,7 @@ 215 215 216 216 Protection against current unbalance of battery modules is configured in the section "Protections - Current unbalance": 217 217 218 -[[image: Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244843-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]]218 +[[image:1734356793451-440.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]] 219 219 220 220 In this section: 221 221 ... ... @@ -234,10 +234,7 @@ 234 234 235 235 * the current of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time. 236 236 237 -(% class="box infomessage" %) 238 -((( 239 -If there is the “Current unbalance (CH)” or "Current unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**. 240 -))) 237 +If there is the error "Current unbalance (CH)" ("Current unbalance (DCH)"), the charging (discharging) contactor of the battery module opens. 241 241 242 242 === Charging current unbalance (in “Charging” state) === 243 243 ... ... @@ -263,10 +263,7 @@ 263 263 264 264 * battery module is included in the largest group of modules with similar charge currents during the “Delay before clearing the error” time. 265 265 266 -(% class="box infomessage" %) 267 -((( 268 -If there is the “Charging current unbalance” error, **corresponding battery module opens its charging contactor**. 269 -))) 263 +If there is the “Charging current unbalance” error, the battery module charging contactor opens. 270 270 271 271 === Discharging current unbalance === 272 272 ... ... @@ -292,19 +292,8 @@ 292 292 293 293 * battery module is included in the largest group of modules with similar discharge currents during the “Delay before clearing the error” time. 294 294 295 -(% class="box infomessage" %) 296 -((( 297 -If there is the “Discharging current unbalance” error, **corresponding battery module opens its discharging contactor**. 298 -))) 289 +If there is the “Discharging current unbalance” error, the battery module discharging contactor opens. 299 299 300 -=== High contactor tempe === 301 - 302 -=== WDT reset === 303 - 304 -If the BMS firmware hangs, the watchdog timer resets the device. The BMS can detect that the device was reset and generates the “WDT reset” error. 305 - 306 -To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 307 - 308 308 === Critical error === 309 309 310 310 Parameters for generating the critical error are configured in the "Protections - Critical error" section: