Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -215,7 +215,7 @@ 215 215 216 216 Protection against current unbalance of battery modules is configured in the section "Protections - Current unbalance": 217 217 218 -[[image:1734 356793451-440.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]]218 +[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244843-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]] 219 219 220 220 In this section: 221 221 ... ... @@ -226,8 +226,10 @@ 226 226 * Check all the time (not only in the ‘Balancing’ state) – a flag to enable voltage check not only in “Balancing” state; 227 227 * Lock – a flag to block the error until the device is restarted. 228 228 229 -As a result of the operation of the current unbalance protection the errors “Current unbalance (CH)” and “Current unbalance (DCH)” are generated. Conditions for generating the error:229 +As a result of the operation of the current unbalance protection the errors “Current unbalance (CH)” and “Current unbalance (DCH)” are generated. 230 230 231 +Conditions for generating the error: 232 + 231 231 * the current of the battery module is greater than the "Maximum current" value during the "Delay before setting the error" time. 232 232 233 233 Conditions for clearing the error: ... ... @@ -234,9 +234,9 @@ 234 234 235 235 * the current of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time. 236 236 237 -(% class="box warningmessage" %)239 +(% class="box infomessage" %) 238 238 ((( 239 -If there is the “Current unbalance” error, **corresponding battery module opens its discharging contactor**. 241 +If there is the “Current unbalance (CH)” or "Current unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**. 240 240 ))) 241 241 242 242 === Charging current unbalance (in “Charging” state) === ... ... @@ -255,8 +255,10 @@ 255 255 * Delay before clearing the error; 256 256 * Lock – a flag to block the error until the device is restarted. 257 257 258 -As a result of the operation of the protection the “Charging current unbalance” are generated. Conditions for generating the errors:260 +As a result of the operation of the protection the “Charging current unbalance” are generated. 259 259 262 +Conditions for generating the errors: 263 + 260 260 * battery module is not included in the largest group of modules whose charge currents differ from each other by no more than "Delta current" during the "Delay before setting the error" time. 261 261 262 262 Conditions for clearing the error: ... ... @@ -284,8 +284,10 @@ 284 284 * Delay before clearing the error; 285 285 * Lock – a flag to block the error until the device is restarted. 286 286 287 -As a result of the operation of the protection the “Discharging current unbalance” are generated. Conditions for generating the errors:291 +As a result of the operation of the protection the “Discharging current unbalance” are generated. 288 288 293 +Conditions for generating the errors: 294 + 289 289 * battery module is not included in the largest group of modules whose discharge currents differ from each other by no more than "Delta current" during the "Delay before setting the error" time. 290 290 291 291 Conditions for clearing the error: ... ... @@ -297,12 +297,62 @@ 297 297 If there is the “Discharging current unbalance” error, **corresponding battery module opens its discharging contactor**. 298 298 ))) 299 299 306 +=== High contactor temperature === 307 + 308 +The BMS Main X device protects power contactors from overheating. To measure the temperature of the contactor, one of the thermistors connected to the X5 connector is used. 309 + 310 +To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 311 + 312 +[[image:1740756362809-292.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="161" width="800"]] 313 + 314 +In this section: 315 + 316 +* Enable – a flag to enable the protection; 317 +* Thermistor – a selection of which cell thermistor will be used as contactor temperature sensor; 318 +* Maximum contactor temperature, °C; 319 +* Tolerant contactor temperature, °C; 320 +* Delay before setting the error, second; 321 +* Delay before clearing the error, second; 322 +* Lock – a flag to block the error until the device is restarted. 323 + 324 +If there is a contactor overheat, the "High contactor temperature" error is generated. 325 + 326 +Error generation conditions: 327 + 328 +* the contactor temperature is greater than the “Maximum contactor temperature” value during the “Delay before setting the error” time. 329 + 330 +Conditions for removing the error: 331 + 332 +* the contactor temperature is lower than the “Tolerant contactor temperature” value during the “Delay before clearing the error” time. 333 + 334 +=== WDT reset === 335 + 336 +If the BMS firmware hangs, the watchdog timer resets the device. The BMS can detect that the device was reset and generates the “WDT reset” error. 337 + 338 +To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 339 + 340 +[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244845-157.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]] 341 + 342 +In this section: 343 + 344 +* Enable – a flag to enable the protection; 345 +* Delay before clearing the error, second; 346 +* Lock – a flag to block the error until the device is restarted. 347 + 348 +Conditions for removing the error: 349 + 350 +* the “Delay before clearing the error” time has passed from the device startup. 351 + 352 +If there is the "WDT reset" error, **“Critical error” is generated.** 353 + 300 300 === Critical error === 301 301 302 - Parametersforgeneratingthe criticalerrorareconfigured inthe "Protections -Critical error"section:356 +Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault. 303 303 304 - [[image:1734356802719-477.png||data-xwiki-image-style-alignment="center"data-xwiki-image-style-border="true"height="69" width="600"]]358 +To change the critical error parameters, select the "Protections → Critical error" section: 305 305 360 +[[image:1740756532131-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]] 361 + 306 306 In this section: 307 307 308 308 * Enable – a flag to enable the protection; ... ... @@ -310,18 +310,6 @@ 310 310 * Delay before clearing the error; 311 311 * Lock – a flag to block the error until the device is restarted. 312 312 313 -The critical errorflag is generated if at least one of thefollowing errorspersistsduring the"Delay before setting the error"time:369 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 314 314 315 -* «Battery cover»; 316 -* «Insulation fault»; 317 -* «CH contactor feedback error»; 318 -* «DCH contactor feedback error»; 319 -* «CH/DCH contactor feedback error»; 320 -* «Module offline». 321 - 322 -The critical error flag is cleared if there are no errors from the list above during the "Delay before clearing the error" time. 323 - 324 -(% class="box warningmessage" %) 325 -((( 326 -**When the critical error flag is present, all battery contactors open.** 327 -))) 371 +The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
- 1740756362809-292.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- 1740756532131-419.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.7 KB - Content