Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -215,7 +215,7 @@ 215 215 216 216 Protection against current unbalance of battery modules is configured in the section "Protections - Current unbalance": 217 217 218 -[[image:1734 356793451-440.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]]218 +[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244843-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]] 219 219 220 220 In this section: 221 221 ... ... @@ -234,7 +234,10 @@ 234 234 235 235 * the current of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time. 236 236 237 -If there is the error "Current unbalance (CH)" ("Current unbalance (DCH)"), the charging (discharging) contactor of the battery module opens. 237 +(% class="box infomessage" %) 238 +((( 239 +If there is the “Current unbalance (CH)” or "Current unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**. 240 +))) 238 238 239 239 === Charging current unbalance (in “Charging” state) === 240 240 ... ... @@ -260,7 +260,10 @@ 260 260 261 261 * battery module is included in the largest group of modules with similar charge currents during the “Delay before clearing the error” time. 262 262 263 -If there is the “Charging current unbalance” error, the battery module charging contactor opens. 266 +(% class="box infomessage" %) 267 +((( 268 +If there is the “Charging current unbalance” error, **corresponding battery module opens its charging contactor**. 269 +))) 264 264 265 265 === Discharging current unbalance === 266 266 ... ... @@ -286,8 +286,19 @@ 286 286 287 287 * battery module is included in the largest group of modules with similar discharge currents during the “Delay before clearing the error” time. 288 288 289 -If there is the “Discharging current unbalance” error, the battery module discharging contactor opens. 295 +(% class="box infomessage" %) 296 +((( 297 +If there is the “Discharging current unbalance” error, **corresponding battery module opens its discharging contactor**. 298 +))) 290 290 300 +=== High contactor temperature === 301 + 302 +=== WDT reset === 303 + 304 +If the BMS firmware hangs, the watchdog timer resets the device. The BMS can detect that the device was reset and generates the “WDT reset” error. 305 + 306 +To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 307 + 291 291 === Critical error === 292 292 293 293 Parameters for generating the critical error are configured in the "Protections - Critical error" section:
- 1740756362809-292.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content