Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -154,61 +154,68 @@ 154 154 155 155 Protection against loss of communication with battery modules is configured in the "Protections - Module offline" section: 156 156 157 -[[image:17 34356793441-881.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="75" width="600"]]157 +[[image:1740754588971-137.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]] 158 158 159 159 In this section: 160 160 161 -* Enable – a flag to enable the protection; 162 -* Delay before setting the error; 163 -* Delay before clearing the error; 164 -* Lock – a flag to block the error until the device is restarted. 161 +* Enable – a flag to enable the protection; 162 +* Number of offline modules to set the error; 163 +* Delay before setting the error, second; 164 +* Delay before clearing the error, second; 165 +* Lock – lock the error until the device is reset. 165 165 166 -As a result of the protection againstloss of communication withthebattery module, the“Module offline”error is generated.Conditions for generating the error:167 +As a result of the protection from loss of communication with battery modules, the "Module offline" error is generated. 167 167 168 - *at least oneof the battery modules doesnotrespond tocommands within the "Delay before setting the error" time.169 +Error generation conditions: 169 169 170 - Conditionsforclearing the error:171 +* more than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main 3X device within “Delay before setting the error” time. 171 171 172 - * all battery modules respondcommandswithin the "Delay beforeclearing the error" time.173 +Conditions for removing the error: 173 173 175 +* less than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main 3X device within “Delay before clearing the error” time. 176 + 174 174 (% class="box warningmessage" %) 175 175 ((( 176 -If there is the "Module offline" error, ** the critical errorflagis generatedand all battery contactors open.**179 +If there is the "Module offline" error, **“Critical error” is generated.** 177 177 ))) 178 178 179 -=== Voltage unbalance === 182 +=== Voltage unbalance (in any state) === 180 180 181 181 Before closing the contactors for charging and discharging battery modules, the BMS Main X device detects those modules whose voltage is significantly different from the rest. For unbalanced modules, errors "Voltage unbalance (CH)" (charge circuit) and "Voltage unbalance (DCH)" (discharge circuit) are generated. 182 182 183 -Protection against voltage unbalance of battery modules is configured in the section "Protections - Voltage unbalance": 186 +Protection against voltage unbalance of battery modules is configured in the section "Protections - Voltage unbalance (in any state)": 184 184 185 -[[image:17 34356793449-249.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="75" width="600"]]188 +[[image:1740754732291-420.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 186 186 187 187 In this section: 188 188 189 189 * Enable – a flag to enable the protection; 190 190 * Delta voltage – maximum allowable voltage difference of battery modules, V; 194 +* Use the open circuit voltage to detect the error – a flag to enable U,,ocv,, correction; 191 191 * Delay before setting the error; 192 192 * Delay before clearing the error; 197 +* Set the 'Voltage unbalance' error for the modules that are not ready to charge/discharge; 193 193 * Lock – a flag to block the error until the device is restarted. 194 194 195 -As a result of the operation of the voltage unbalance protection the errors “Voltage unbalance (CH)” and “Voltage unbalance (DCH)” are generated. Conditions for generating the error:200 +As a result of the operation of the voltage unbalance protection the errors “Voltage unbalance (CH)” and “Voltage unbalance (DCH)” are generated. 196 196 197 - * battery moduleis notcluded in the largestgroup ofmodules whose voltages differfrom each other by no more than "Delta voltage" during the"Delay before setting the error" time.202 +Conditions for generating the error: 198 198 204 +* battery module is not included in the largest group of modules whose voltages differ from each other by no more than "Delta voltage" during the "Delay before setting the error" time; 205 +* module is not ready to charge or discharge; 206 + 199 199 Conditions for clearing the error: 200 200 201 -* battery module is in the largest group of balanced modules during the "Delay before clearing the error" time. 209 +* battery module is in the largest group of balanced modules during the "Delay before clearing the error" time; 210 +* module is ready to charge or discharge. 202 202 203 - Ifthereistheerror "Voltageunbalance (CH)"("Voltage unbalance (DCH)"), the charging(discharging) contactor of thebattery module opens.212 +=== Current unbalance (in “Balancing” state) === 204 204 205 -=== Current unbalance === 206 - 207 207 When battery modules are connected in parallel, the most charged modules transfer charge to the least charged modules. The process of charge transfer is accompanied by the flow of balancing currents. The BMS Main X device detects modules with high balancing currents and generates “Current unbalance (CH)” (charge circuit) and “Current unbalance (DCH)” (discharge circuit) errors for them. 208 208 209 209 Protection against current unbalance of battery modules is configured in the section "Protections - Current unbalance": 210 210 211 -[[image:1734 356793451-440.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="77" width="600"]]218 +[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244843-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]] 212 212 213 213 In this section: 214 214 ... ... @@ -216,19 +216,23 @@ 216 216 * Maximum current – a maximum allowable self-balancing current of battery modules, A; 217 217 * Delay before setting the error; 218 218 * Delay before clearing the error; 226 +* Check all the time (not only in the ‘Balancing’ state) – a flag to enable voltage check not only in “Balancing” state; 219 219 * Lock – a flag to block the error until the device is restarted. 220 220 221 221 As a result of the operation of the current unbalance protection the errors “Current unbalance (CH)” and “Current unbalance (DCH)” are generated. Conditions for generating the error: 222 222 223 -* current of the battery module is greater than the "Maximum current" value during the "Delay before setting the error" time. 231 +* the current of the battery module is greater than the "Maximum current" value during the "Delay before setting the error" time. 224 224 225 225 Conditions for clearing the error: 226 226 227 -* current of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time. 235 +* the current of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time. 228 228 229 -If there is the error "Current unbalance (CH)" ("Current unbalance (DCH)"), the charging (discharging) contactor of the battery module opens. 237 +(% class="box infomessage" %) 238 +((( 239 +If there is the “Current unbalance (CH)” or "Current unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**. 240 +))) 230 230 231 -=== Charging current unbalance === 242 +=== Charging current unbalance (in “Charging” state) === 232 232 233 233 During battery charging, the currents of the battery modules may vary. The BMS Main X device detects modules whose charging currents are significantly different from the currents of other modules and generates the “Charging current unbalance” errors for them. 234 234 ... ... @@ -252,7 +252,10 @@ 252 252 253 253 * battery module is included in the largest group of modules with similar charge currents during the “Delay before clearing the error” time. 254 254 255 -If there is the “Charging current unbalance” error, the battery module charging contactor opens. 266 +(% class="box infomessage" %) 267 +((( 268 +If there is the “Charging current unbalance” error, **corresponding battery module opens its charging contactor**. 269 +))) 256 256 257 257 === Discharging current unbalance === 258 258 ... ... @@ -278,8 +278,19 @@ 278 278 279 279 * battery module is included in the largest group of modules with similar discharge currents during the “Delay before clearing the error” time. 280 280 281 -If there is the “Discharging current unbalance” error, the battery module discharging contactor opens. 295 +(% class="box infomessage" %) 296 +((( 297 +If there is the “Discharging current unbalance” error, **corresponding battery module opens its discharging contactor**. 298 +))) 282 282 300 +=== High contactor temperature === 301 + 302 +=== WDT reset === 303 + 304 +If the BMS firmware hangs, the watchdog timer resets the device. The BMS can detect that the device was reset and generates the “WDT reset” error. 305 + 306 +To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 307 + 283 283 === Critical error === 284 284 285 285 Parameters for generating the critical error are configured in the "Protections - Critical error" section:
- 1740754732291-420.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.4 KB - Content
- 1740756362809-292.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content