Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -154,35 +154,38 @@ 154 154 155 155 Protection against loss of communication with battery modules is configured in the "Protections - Module offline" section: 156 156 157 -[[image:17 34356793441-881.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="75" width="600"]]157 +[[image:1740754588971-137.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]] 158 158 159 159 In this section: 160 160 161 -* Enable – a flag to enable the protection; 162 -* Delay before setting the error; 163 -* Delay before clearing the error; 164 -* Lock – a flag to block the error until the device is restarted. 161 +* Enable – a flag to enable the protection; 162 +* Number of offline modules to set the error; 163 +* Delay before setting the error, second; 164 +* Delay before clearing the error, second; 165 +* Lock – lock the error until the device is reset. 165 165 166 -As a result of the protection againstloss of communication withthebattery module, the“Module offline”error is generated.Conditions for generating the error:167 +As a result of the protection from loss of communication with battery modules, the "Module offline" error is generated. 167 167 168 - *at least oneof the battery modules doesnotrespond tocommands within the "Delay before setting the error" time.169 +Error generation conditions: 169 169 170 - Conditionsforclearing the error:171 +* more than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main 3X device within “Delay before setting the error” time. 171 171 172 - * all battery modules respondcommandswithin the "Delay beforeclearing the error" time.173 +Conditions for removing the error: 173 173 175 +* less than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main 3X device within “Delay before clearing the error” time. 176 + 174 174 (% class="box warningmessage" %) 175 175 ((( 176 -If there is the "Module offline" error, ** the critical errorflagis generatedand all battery contactors open.**179 +If there is the "Module offline" error, **“Critical error” is generated.** 177 177 ))) 178 178 179 -=== Voltage unbalance === 182 +=== Voltage unbalance (in any state) === 180 180 181 181 Before closing the contactors for charging and discharging battery modules, the BMS Main X device detects those modules whose voltage is significantly different from the rest. For unbalanced modules, errors "Voltage unbalance (CH)" (charge circuit) and "Voltage unbalance (DCH)" (discharge circuit) are generated. 182 182 183 -Protection against voltage unbalance of battery modules is configured in the section "Protections - Voltage unbalance": 186 +Protection against voltage unbalance of battery modules is configured in the section "Protections - Voltage unbalance (in any state)": 184 184 185 -[[image:1734356793449-249.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 75" width="600"]]188 +[[image:1734356793449-249.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 186 186 187 187 In this section: 188 188 ... ... @@ -192,8 +192,10 @@ 192 192 * Delay before clearing the error; 193 193 * Lock – a flag to block the error until the device is restarted. 194 194 195 -As a result of the operation of the voltage unbalance protection the errors “Voltage unbalance (CH)” and “Voltage unbalance (DCH)” are generated. Conditions for generating the error:198 +As a result of the operation of the voltage unbalance protection the errors “Voltage unbalance (CH)” and “Voltage unbalance (DCH)” are generated. 196 196 200 +Conditions for generating the error: 201 + 197 197 * battery module is not included in the largest group of modules whose voltages differ from each other by no more than "Delta voltage" during the "Delay before setting the error" time. 198 198 199 199 Conditions for clearing the error: ... ... @@ -200,15 +200,13 @@ 200 200 201 201 * battery module is in the largest group of balanced modules during the "Delay before clearing the error" time. 202 202 203 - Ifthereistheerror "Voltageunbalance (CH)"("Voltage unbalance (DCH)"), the charging(discharging) contactor of thebattery module opens.208 +=== Current unbalance (in “Balancing” state) === 204 204 205 -=== Current unbalance === 206 - 207 207 When battery modules are connected in parallel, the most charged modules transfer charge to the least charged modules. The process of charge transfer is accompanied by the flow of balancing currents. The BMS Main X device detects modules with high balancing currents and generates “Current unbalance (CH)” (charge circuit) and “Current unbalance (DCH)” (discharge circuit) errors for them. 208 208 209 209 Protection against current unbalance of battery modules is configured in the section "Protections - Current unbalance": 210 210 211 -[[image:1734356793451-440.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 77" width="600"]]214 +[[image:1734356793451-440.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]] 212 212 213 213 In this section: 214 214
- 1740754732291-420.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.4 KB - Content