Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,52 +20,7 @@ 20 20 21 21 [[image:1740754371437-635.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="142" width="800"]] 22 22 23 -In this section: 24 24 25 -* Enable – a flag to enable the protection; 26 -* Threshold to switch from Region 1 to Region 2 – a threshold current value, dividing regions 1 and 2 with their error generation conditions, A; 27 -* Region 1: Current difference – an absolute difference of measured battery current and calculated value “Charge current limit”, at which error is generated (condition for Region 1), A; 28 -* Region 2: Current difference – a relative difference of measured battery current and calculated value “Charge current limit”, at which error is generated (conditions for Region 2), %; 29 -* Delay before setting the error, millisecond; 30 -* Delay before clearing the error, second; 31 -* Lock – a flag to block the error until the device is restarted. 32 - 33 -As a result of the operation of the charging current limit protection, the “Current limit error (CH)” is generated. 34 - 35 -Error generation conditions: 36 - 37 -* if the current is positive, less than “Threshold to switch from Region 1 to Region 2” value and exceeds “Charge current limit” by the “Region 1: Current difference” value during the “Delay before setting the error” time; 38 -* if the current is positive, more than “Threshold to switch from Region 1 to Region 2” value and exceeds “Charge current limit” by the (“Region 2: Current difference” × “Charge current limit”) / 100 value during the “Delay before setting the error” time. 39 - 40 -Error is cleared if conditions for generating an error do not apply during the “Delay before clearing the error” time. 41 - 42 -=== Discharging current limit === 43 - 44 -The BMS Main X device protects the battery from discharging current higher than estimated current limit. 45 - 46 -To configure parameters of the charge current limit, select the "Protections → Discharge current limit " section: 47 - 48 -[[image:1740754420820-767.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 49 - 50 -In this section: 51 - 52 -* Enable – a flag to enable the protection; 53 -* Threshold to switch from Region 1 to Region 2 – a threshold current value, dividing regions 1 and 2 with their error generation conditions, A; 54 -* Region 1: Current difference – an absolute difference of measured battery current and calculated value “Discharge current limit”, at which error is generated (condition for Region 1), A; 55 -* Region 2: Current difference – a relative difference of measured battery current and calculated value “Discharge current limit”, at which error is generated (conditions for Region 2), %; 56 -* Delay before setting the error, millisecond; 57 -* Delay before clearing the error, second; 58 -* Lock – a flag to block the error until the device is restarted. 59 - 60 -As a result of the operation of the charging current limit protection, the “Current limit error (DCH)” is generated. 61 - 62 -Error generation conditions: 63 - 64 -* if the current is negative, and the current modulus is less than “Threshold to switch from Region 1 to Region 2” value and exceeds “Discharge current limit” by the “Region 1: Current difference” value during the “Delay before setting the error” time; 65 -* if the current is negative, and the current modulus is more than “Threshold to switch from Region 1 to Region 2” value and exceeds “Discharge current limit” by the (“Region 2: Current difference” × “Discharge current limit”) / 100 value during the “Delay before setting the error” time. 66 - 67 -Error is cleared if conditions for generating an error do not apply during the “Delay before clearing the error” time. 68 - 69 69 === Battery cover === 70 70 71 71 The BMS Main X device detects the opening of the battery cover and performs a protective opening of the contactors. ... ... @@ -72,7 +72,7 @@ 72 72 73 73 Battery cover protection is configured in the "Protections - Battery cover" section: 74 74 75 -[[image:1734356776691-451.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 88" width="800"]]30 +[[image:1734356776691-451.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="66" width="600"]] 76 76 77 77 In this section: 78 78 ... ... @@ -91,7 +91,7 @@ 91 91 92 92 (% class="box warningmessage" %) 93 93 ((( 94 -If there is the "Battery cover" error, the **"Critical error flag" is generated.** 49 +If there is the "Battery cover" error, the **"Critical error flag" is generated and all battery contactors open.** 95 95 ))) 96 96 97 97 === Insulation === ... ... @@ -100,24 +100,26 @@ 100 100 101 101 Insulation protection is configured in the "Protections - Insulation" section: 102 102 103 -[[image:174 0754491323-815.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="121" width="800"]]58 +[[image:1734356776694-257.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="600"]] 104 104 105 105 In this section: 106 106 107 -* Enable – a flag to enable the protection; 108 -* Checking algorithm – isolation checking mode: 109 -** Always on – check is always performed; 110 -** On charging – check is performed only if the “Charge request” is set; 111 -** Except charging - check is performed only if the “Charge request” is cleared; 112 -* Delay before setting the error, second; 113 -* Delay before clearing the error, second; 62 +* Enable – a flag to enable the protection; 63 +* Delay before setting the error; 64 +* Delay before clearing the error; 114 114 * Lock – a flag to block the error until the device is restarted. 115 115 116 - The “Insulationfault”is set if the “Insulationstatus” signal is detected during the“Delay beforesettingthe error”time. The“Insulationstatus” signalcan bereceived throughthediscreteinputor bytheCAN bus from an insulation monitoringdevice. The“Insulation fault” iscleared ifthe “Insulationtatus”signal is clearedduringthe“Delay before clearing the error” time.67 +As a result of the operation of the insulation fault protection, the error “Insulation fault” is generated. Conditions for generating the error: 117 117 69 +* presence of the “Insulation status” signal during the “Delay before setting the error” time. 70 + 71 +Conditions for clearing the error: 72 + 73 +* no “Insulation status” signal during the “Delay before clearing the error” time. 74 + 118 118 (% class="box warningmessage" %) 119 119 ((( 120 -If there is the "Insulation fault" error, **the critical error flag is generated.** 77 +If there is the "Insulation fault" error, **the critical error flag is generated and all battery contactors open.** 121 121 ))) 122 122 123 123 === Contactor feedback === ... ... @@ -126,7 +126,7 @@ 126 126 127 127 Contactor feedback protection is configured in the “Protections – Contactor feedback” section: 128 128 129 -[[image:1734356776695-557.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 89" width="800"]]86 +[[image:1734356776695-557.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="600"]] 130 130 131 131 In this section: 132 132 ... ... @@ -145,7 +145,7 @@ 145 145 146 146 (% class="box warningmessage" %) 147 147 ((( 148 -If there is the “CH contactor feedback error”, “DCH contactor feedback error”, or “CH/DCH contactor feedback error”, **the critical error flag is generated.** 105 +If there is the “CH contactor feedback error”, “DCH contactor feedback error”, or “CH/DCH contactor feedback error”, **the critical error flag is generated and all battery contactors open.** 149 149 ))) 150 150 151 151 === Module offline ===
- 1740754491323-815.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.2 KB - Content
- 1740754588971-137.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -18.4 KB - Content