Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -100,24 +100,26 @@ 100 100 101 101 Insulation protection is configured in the "Protections - Insulation" section: 102 102 103 -[[image:174 0754491323-815.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="121" width="800"]]103 +[[image:1734356776694-257.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="68" width="600"]] 104 104 105 105 In this section: 106 106 107 -* Enable – a flag to enable the protection; 108 -* Checking algorithm – isolation checking mode: 109 -** Always on – check is always performed; 110 -** On charging – check is performed only if the “Charge request” is set; 111 -** Except charging - check is performed only if the “Charge request” is cleared; 112 -* Delay before setting the error, second; 113 -* Delay before clearing the error, second; 107 +* Enable – a flag to enable the protection; 108 +* Delay before setting the error; 109 +* Delay before clearing the error; 114 114 * Lock – a flag to block the error until the device is restarted. 115 115 116 - The “Insulationfault”is set if the “Insulationstatus” signal is detected during the“Delay beforesettingthe error”time. The“Insulationstatus” signalcan bereceived throughthediscreteinputor bytheCAN bus from an insulation monitoringdevice. The“Insulation fault” iscleared ifthe “Insulationtatus”signal is clearedduringthe“Delay before clearing the error” time.112 +As a result of the operation of the insulation fault protection, the error “Insulation fault” is generated. Conditions for generating the error: 117 117 114 +* presence of the “Insulation status” signal during the “Delay before setting the error” time. 115 + 116 +Conditions for clearing the error: 117 + 118 +* no “Insulation status” signal during the “Delay before clearing the error” time. 119 + 118 118 (% class="box warningmessage" %) 119 119 ((( 120 -If there is the "Insulation fault" error, **the critical error flag is generated.** 122 +If there is the "Insulation fault" error, **the critical error flag is generated and all battery contactors open.** 121 121 ))) 122 122 123 123 === Contactor feedback === ... ... @@ -126,7 +126,7 @@ 126 126 127 127 Contactor feedback protection is configured in the “Protections – Contactor feedback” section: 128 128 129 -[[image:1734356776695-557.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 89" width="800"]]131 +[[image:1734356776695-557.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="600"]] 130 130 131 131 In this section: 132 132 ... ... @@ -145,7 +145,7 @@ 145 145 146 146 (% class="box warningmessage" %) 147 147 ((( 148 -If there is the “CH contactor feedback error”, “DCH contactor feedback error”, or “CH/DCH contactor feedback error”, **the critical error flag is generated.** 150 +If there is the “CH contactor feedback error”, “DCH contactor feedback error”, or “CH/DCH contactor feedback error”, **the critical error flag is generated and all battery contactors open.** 149 149 ))) 150 150 151 151 === Module offline ===
- 1740754491323-815.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.2 KB - Content