Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,52 +20,7 @@ 20 20 21 21 [[image:1740754371437-635.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="142" width="800"]] 22 22 23 -In this section: 24 24 25 -* Enable – a flag to enable the protection; 26 -* Threshold to switch from Region 1 to Region 2 – a threshold current value, dividing regions 1 and 2 with their error generation conditions, A; 27 -* Region 1: Current difference – an absolute difference of measured battery current and calculated value “Charge current limit”, at which error is generated (condition for Region 1), A; 28 -* Region 2: Current difference – a relative difference of measured battery current and calculated value “Charge current limit”, at which error is generated (conditions for Region 2), %; 29 -* Delay before setting the error, millisecond; 30 -* Delay before clearing the error, second; 31 -* Lock – a flag to block the error until the device is restarted. 32 - 33 -As a result of the operation of the charging current limit protection, the “Current limit error (CH)” is generated. 34 - 35 -Error generation conditions: 36 - 37 -* if the current is positive, less than “Threshold to switch from Region 1 to Region 2” value and exceeds “Charge current limit” by the “Region 1: Current difference” value during the “Delay before setting the error” time; 38 -* if the current is positive, more than “Threshold to switch from Region 1 to Region 2” value and exceeds “Charge current limit” by the (“Region 2: Current difference” × “Charge current limit”) / 100 value during the “Delay before setting the error” time. 39 - 40 -Error is cleared if conditions for generating an error do not apply during the “Delay before clearing the error” time. 41 - 42 -=== Discharging current limit === 43 - 44 -The BMS Main X device protects the battery from discharging current higher than estimated current limit. 45 - 46 -To configure parameters of the charge current limit, select the "Protections → Discharge current limit " section: 47 - 48 -[[image:1740754420820-767.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 49 - 50 -In this section: 51 - 52 -* Enable – a flag to enable the protection; 53 -* Threshold to switch from Region 1 to Region 2 – a threshold current value, dividing regions 1 and 2 with their error generation conditions, A; 54 -* Region 1: Current difference – an absolute difference of measured battery current and calculated value “Discharge current limit”, at which error is generated (condition for Region 1), A; 55 -* Region 2: Current difference – a relative difference of measured battery current and calculated value “Discharge current limit”, at which error is generated (conditions for Region 2), %; 56 -* Delay before setting the error, millisecond; 57 -* Delay before clearing the error, second; 58 -* Lock – a flag to block the error until the device is restarted. 59 - 60 -As a result of the operation of the charging current limit protection, the “Current limit error (DCH)” is generated. 61 - 62 -Error generation conditions: 63 - 64 -* if the current is negative, and the current modulus is less than “Threshold to switch from Region 1 to Region 2” value and exceeds “Discharge current limit” by the “Region 1: Current difference” value during the “Delay before setting the error” time; 65 -* if the current is negative, and the current modulus is more than “Threshold to switch from Region 1 to Region 2” value and exceeds “Discharge current limit” by the (“Region 2: Current difference” × “Discharge current limit”) / 100 value during the “Delay before setting the error” time. 66 - 67 -Error is cleared if conditions for generating an error do not apply during the “Delay before clearing the error” time. 68 - 69 69 === Battery cover === 70 70 71 71 The BMS Main X device detects the opening of the battery cover and performs a protective opening of the contactors. ... ... @@ -72,7 +72,7 @@ 72 72 73 73 Battery cover protection is configured in the "Protections - Battery cover" section: 74 74 75 -[[image:1734356776691-451.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 88" width="800"]]30 +[[image:1734356776691-451.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="66" width="600"]] 76 76 77 77 In this section: 78 78 ... ... @@ -91,7 +91,7 @@ 91 91 92 92 (% class="box warningmessage" %) 93 93 ((( 94 -If there is the "Battery cover" error, the **"Critical error flag" is generated.** 49 +If there is the "Battery cover" error, the **"Critical error flag" is generated and all battery contactors open.** 95 95 ))) 96 96 97 97 === Insulation ===