... ... @@ -6,6 +6,66 @@
6 6  
7 7  The BMS Main X monitors the battery modules, compares the voltages and currents of the modules, and protects the battery system from damage.
8 8  
9 +(% class="box errormessage" %)
10 +(((
11 +**Attention!**
12 +Behavior of contactors at different errors is configured in **corresponding contactor settings**!
13 +)))
14 +
15 +=== Charging current limit ===
16 +
17 +The BMS Main X device protects the battery from charging current higher than estimated current limit.
18 +
19 +To configure parameters of the charge current limit, select the "Protections → Charge current limit" section:
20 +
21 +[[image:1740754371437-635.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="142" width="800"]]
22 +
23 +In this section:
24 +
25 +* Enable – a flag to enable the protection;
26 +* Threshold to switch from Region 1 to Region 2 – a threshold current value, dividing regions 1 and 2 with their error generation conditions, A;
27 +* Region 1: Current difference – an absolute difference of measured battery current and calculated value “Charge current limit”, at which error is generated (condition for Region 1), A;
28 +* Region 2: Current difference – a relative difference of measured battery current and calculated value “Charge current limit”, at which error is generated (conditions for Region 2), %;
29 +* Delay before setting the error, millisecond;
30 +* Delay before clearing the error, second;
31 +* Lock – a flag to block the error until the device is restarted.
32 +
33 +As a result of the operation of the charging current limit protection, the “Current limit error (CH)” is generated.
34 +
35 +Error generation conditions:
36 +
37 +* if the current is positive, less than “Threshold to switch from Region 1 to Region 2” value and exceeds “Charge current limit” by the “Region 1: Current difference” value during the “Delay before setting the error” time;
38 +* if the current is positive, more than “Threshold to switch from Region 1 to Region 2” value and exceeds “Charge current limit” by the (“Region 2: Current difference” × “Charge current limit”) / 100 value during the “Delay before setting the error” time.
39 +
40 +Error is cleared if conditions for generating an error do not apply during the “Delay before clearing the error” time.
41 +
42 +=== Discharging current limit ===
43 +
44 +The BMS Main X device protects the battery from discharging current higher than estimated current limit.
45 +
46 +To configure parameters of the charge current limit, select the "Protections → Discharge current limit " section:
47 +
48 +[[image:1740754420820-767.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
49 +
50 +In this section:
51 +
52 +* Enable – a flag to enable the protection;
53 +* Threshold to switch from Region 1 to Region 2 – a threshold current value, dividing regions 1 and 2 with their error generation conditions, A;
54 +* Region 1: Current difference – an absolute difference of measured battery current and calculated value “Discharge current limit”, at which error is generated (condition for Region 1), A;
55 +* Region 2: Current difference – a relative difference of measured battery current and calculated value “Discharge current limit”, at which error is generated (conditions for Region 2), %;
56 +* Delay before setting the error, millisecond;
57 +* Delay before clearing the error, second;
58 +* Lock – a flag to block the error until the device is restarted.
59 +
60 +As a result of the operation of the charging current limit protection, the “Current limit error (DCH)” is generated.
61 +
62 +Error generation conditions:
63 +
64 +* if the current is negative, and the current modulus is less than “Threshold to switch from Region 1 to Region 2” value and exceeds “Discharge current limit” by the “Region 1: Current difference” value during the “Delay before setting the error” time;
65 +* if the current is negative, and the current modulus is more than “Threshold to switch from Region 1 to Region 2” value and exceeds “Discharge current limit” by the (“Region 2: Current difference” × “Discharge current limit”) / 100 value during the “Delay before setting the error” time.
66 +
67 +Error is cleared if conditions for generating an error do not apply during the “Delay before clearing the error” time.
68 +
9 9  === Battery cover ===
10 10  
11 11  The BMS Main X device detects the opening of the battery cover and performs a protective opening of the contactors.
... ... @@ -12,7 +12,7 @@
12 12  
13 13  Battery cover protection is configured in the "Protections - Battery cover" section:
14 14  
15 -[[image:1734356776691-451.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="66" width="600"]]
75 +[[image:1734356776691-451.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="88" width="800"]]
16 16  
17 17  In this section:
18 18  
... ... @@ -31,7 +31,7 @@
31 31  
32 32  (% class="box warningmessage" %)
33 33  (((
34 -If there is the "Battery cover" error, the **"Critical error flag" is generated and all battery contactors open.**
94 +If there is the "Battery cover" error, the **"Critical error flag" is generated.**
35 35  )))
36 36  
37 37  === Insulation ===
1740754371437-635.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +21.7 KB
Content
1740754420820-767.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +22.3 KB
Content
1740754491323-815.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.2 KB
Content