Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,6 +6,66 @@ 6 6 7 7 The BMS Main X monitors the battery modules, compares the voltages and currents of the modules, and protects the battery system from damage. 8 8 9 +(% class="box errormessage" %) 10 +((( 11 +**Attention!** 12 +Behavior of contactors at different errors is configured in **corresponding contactor settings**! 13 +))) 14 + 15 +=== Charging current limit === 16 + 17 +The BMS Main X device protects the battery from charging current higher than estimated current limit. 18 + 19 +To configure parameters of the charge current limit, select the "Protections → Charge current limit" section: 20 + 21 +[[image:1740754371437-635.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="142" width="800"]] 22 + 23 +In this section: 24 + 25 +* Enable – a flag to enable the protection; 26 +* Threshold to switch from Region 1 to Region 2 – a threshold current value, dividing regions 1 and 2 with their error generation conditions, A; 27 +* Region 1: Current difference – an absolute difference of measured battery current and calculated value “Charge current limit”, at which error is generated (condition for Region 1), A; 28 +* Region 2: Current difference – a relative difference of measured battery current and calculated value “Charge current limit”, at which error is generated (conditions for Region 2), %; 29 +* Delay before setting the error, millisecond; 30 +* Delay before clearing the error, second; 31 +* Lock – a flag to block the error until the device is restarted. 32 + 33 +As a result of the operation of the charging current limit protection, the “Current limit error (CH)” is generated. 34 + 35 +Error generation conditions: 36 + 37 +* if the current is positive, less than “Threshold to switch from Region 1 to Region 2” value and exceeds “Charge current limit” by the “Region 1: Current difference” value during the “Delay before setting the error” time; 38 +* if the current is positive, more than “Threshold to switch from Region 1 to Region 2” value and exceeds “Charge current limit” by the (“Region 2: Current difference” × “Charge current limit”) / 100 value during the “Delay before setting the error” time. 39 + 40 +Error is cleared if conditions for generating an error do not apply during the “Delay before clearing the error” time. 41 + 42 +=== Discharging current limit === 43 + 44 +The BMS Main X device protects the battery from discharging current higher than estimated current limit. 45 + 46 +To configure parameters of the charge current limit, select the "Protections → Discharge current limit " section: 47 + 48 +[[image:1740754420820-767.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 49 + 50 +In this section: 51 + 52 +* Enable – a flag to enable the protection; 53 +* Threshold to switch from Region 1 to Region 2 – a threshold current value, dividing regions 1 and 2 with their error generation conditions, A; 54 +* Region 1: Current difference – an absolute difference of measured battery current and calculated value “Discharge current limit”, at which error is generated (condition for Region 1), A; 55 +* Region 2: Current difference – a relative difference of measured battery current and calculated value “Discharge current limit”, at which error is generated (conditions for Region 2), %; 56 +* Delay before setting the error, millisecond; 57 +* Delay before clearing the error, second; 58 +* Lock – a flag to block the error until the device is restarted. 59 + 60 +As a result of the operation of the charging current limit protection, the “Current limit error (DCH)” is generated. 61 + 62 +Error generation conditions: 63 + 64 +* if the current is negative, and the current modulus is less than “Threshold to switch from Region 1 to Region 2” value and exceeds “Discharge current limit” by the “Region 1: Current difference” value during the “Delay before setting the error” time; 65 +* if the current is negative, and the current modulus is more than “Threshold to switch from Region 1 to Region 2” value and exceeds “Discharge current limit” by the (“Region 2: Current difference” × “Discharge current limit”) / 100 value during the “Delay before setting the error” time. 66 + 67 +Error is cleared if conditions for generating an error do not apply during the “Delay before clearing the error” time. 68 + 9 9 === Battery cover === 10 10 11 11 The BMS Main X device detects the opening of the battery cover and performs a protective opening of the contactors. ... ... @@ -12,7 +12,7 @@ 12 12 13 13 Battery cover protection is configured in the "Protections - Battery cover" section: 14 14 15 -[[image:1734356776691-451.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 66" width="600"]]75 +[[image:1734356776691-451.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="88" width="800"]] 16 16 17 17 In this section: 18 18 ... ... @@ -31,7 +31,7 @@ 31 31 32 32 (% class="box warningmessage" %) 33 33 ((( 34 -If there is the "Battery cover" error, the **"Critical error flag" is generated and all battery contactors open.**94 +If there is the "Battery cover" error, the **"Critical error flag" is generated.** 35 35 ))) 36 36 37 37 === Insulation ===
- 1740754371437-635.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.7 KB - Content
- 1740754420820-767.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.3 KB - Content
- 1740754491323-815.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.2 KB - Content