... ... @@ -191,7 +191,7 @@ 191 191 192 192 * Enable – a flag to enable the protection; 193 193 * Delta voltage – maximum allowable voltage difference of battery modules, V; 194 -* Use the open circuit voltage to detect the error – a flag to usethe U,,ocv,,(corrected due to current and module resistance) module voltage;194 +* Use the open circuit voltage to detect the error – a flag to enable U,,ocv,, correction; 195 195 * Delay before setting the error; 196 196 * Delay before clearing the error; 197 197 * Set the 'Voltage unbalance' error for the modules that are not ready to charge/discharge;