... ... @@ -168,11 +168,11 @@ 168 168 169 169 Error generation conditions: 170 170 171 -* more than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main X device within “Delay before setting the error” time. 171 +* more than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main 3X device within “Delay before setting the error” time. 172 172 173 173 Conditions for removing the error: 174 174 175 -* less than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main X device within “Delay before clearing the error” time. 175 +* less than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main 3X device within “Delay before clearing the error” time. 176 176 177 177 (% class="box warningmessage" %) 178 178 ((( ... ... @@ -191,10 +191,10 @@ 191 191 192 192 * Enable – a flag to enable the protection; 193 193 * Delta voltage – maximum allowable voltage difference of battery modules, V; 194 -* Use the open circuit voltage to detect the error – a flag to enable U ,,ocv,,correction;194 +* Use the open circuit voltage to detect the error – a flag to enable Uocv correction; 195 195 * Delay before setting the error; 196 196 * Delay before clearing the error; 197 -* Set the 'Voltage unbalance'error for the modules that are not ready to charge/discharge;197 +* Set the 'Voltage ' 198 198 * Lock – a flag to block the error until the device is restarted. 199 199 200 200 As a result of the operation of the voltage unbalance protection the errors “Voltage unbalance (CH)” and “Voltage unbalance (DCH)” are generated. ... ... @@ -201,19 +201,12 @@ 201 201 202 202 Conditions for generating the error: 203 203 204 -* battery module is not included in the largest group of modules whose voltages differ from each other by no more than "Delta voltage" during the "Delay before setting the error" time; 205 -* module is not ready to charge or discharge; 204 +* battery module is not included in the largest group of modules whose voltages differ from each other by no more than "Delta voltage" during the "Delay before setting the error" time. 206 206 207 207 Conditions for clearing the error: 208 208 209 -* battery module is in the largest group of balanced modules during the "Delay before clearing the error" time; 210 -* module is ready to charge or discharge. 208 +* battery module is in the largest group of balanced modules during the "Delay before clearing the error" time. 211 211 212 -(% class="box infomessage" %) 213 -((( 214 -If there is the “Voltage unbalance (CH)” or "Voltage unbalance (DCH)" error, **corresponding battery module do not close its contactors while joining to charge of discharge**. 215 -))) 216 - 217 217 === Current unbalance (in “Balancing” state) === 218 218 219 219 When battery modules are connected in parallel, the most charged modules transfer charge to the least charged modules. The process of charge transfer is accompanied by the flow of balancing currents. The BMS Main X device detects modules with high balancing currents and generates “Current unbalance (CH)” (charge circuit) and “Current unbalance (DCH)” (discharge circuit) errors for them. ... ... @@ -220,7 +220,7 @@ 220 220 221 221 Protection against current unbalance of battery modules is configured in the section "Protections - Current unbalance": 222 222 223 -[[image: Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244843-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]]216 +[[image:1734356793451-440.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]] 224 224 225 225 In this section: 226 226 ... ... @@ -228,25 +228,19 @@ 228 228 * Maximum current – a maximum allowable self-balancing current of battery modules, A; 229 229 * Delay before setting the error; 230 230 * Delay before clearing the error; 231 -* Check all the time (not only in the ‘Balancing’ state) – a flag to enable voltage check not only in “Balancing” state; 232 232 * Lock – a flag to block the error until the device is restarted. 233 233 234 -As a result of the operation of the current unbalance protection the errors “Current unbalance (CH)” and “Current unbalance (DCH)” are generated. 226 +As a result of the operation of the current unbalance protection the errors “Current unbalance (CH)” and “Current unbalance (DCH)” are generated. Conditions for generating the error: 235 235 236 - Conditionsfor generating the error:228 +* current of the battery module is greater than the "Maximum current" value during the "Delay before setting the error" time. 237 237 238 -* the current of the battery module is greater than the "Maximum current" value during the "Delay before setting the error" time. 239 - 240 240 Conditions for clearing the error: 241 241 242 -* thecurrent of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time.232 +* current of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time. 243 243 244 -(% class="box infomessage" %) 245 -((( 246 -If there is the “Current unbalance (CH)” or "Current unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**. 247 -))) 234 +If there is the error "Current unbalance (CH)" ("Current unbalance (DCH)"), the charging (discharging) contactor of the battery module opens. 248 248 249 -=== Charging current unbalance (in “Charging” state)===236 +=== Charging current unbalance === 250 250 251 251 During battery charging, the currents of the battery modules may vary. The BMS Main X device detects modules whose charging currents are significantly different from the currents of other modules and generates the “Charging current unbalance” errors for them. 252 252 ... ... @@ -262,10 +262,8 @@ 262 262 * Delay before clearing the error; 263 263 * Lock – a flag to block the error until the device is restarted. 264 264 265 -As a result of the operation of the protection the “Charging current unbalance” are generated. 252 +As a result of the operation of the protection the “Charging current unbalance” are generated. Conditions for generating the errors: 266 266 267 -Conditions for generating the errors: 268 - 269 269 * battery module is not included in the largest group of modules whose charge currents differ from each other by no more than "Delta current" during the "Delay before setting the error" time. 270 270 271 271 Conditions for clearing the error: ... ... @@ -272,10 +272,7 @@ 272 272 273 273 * battery module is included in the largest group of modules with similar charge currents during the “Delay before clearing the error” time. 274 274 275 -(% class="box infomessage" %) 276 -((( 277 -If there is the “Charging current unbalance” error, **corresponding battery module opens its charging contactor**. 278 -))) 260 +If there is the “Charging current unbalance” error, the battery module charging contactor opens. 279 279 280 280 === Discharging current unbalance === 281 281 ... ... @@ -293,10 +293,8 @@ 293 293 * Delay before clearing the error; 294 294 * Lock – a flag to block the error until the device is restarted. 295 295 296 -As a result of the operation of the protection the “Discharging current unbalance” are generated. 278 +As a result of the operation of the protection the “Discharging current unbalance” are generated. Conditions for generating the errors: 297 297 298 -Conditions for generating the errors: 299 - 300 300 * battery module is not included in the largest group of modules whose discharge currents differ from each other by no more than "Delta current" during the "Delay before setting the error" time. 301 301 302 302 Conditions for clearing the error: ... ... @@ -303,77 +303,33 @@ 303 303 304 304 * battery module is included in the largest group of modules with similar discharge currents during the “Delay before clearing the error” time. 305 305 306 -(% class="box infomessage" %) 307 -((( 308 -If there is the “Discharging current unbalance” error, **corresponding battery module opens its discharging contactor**. 309 -))) 286 +If there is the “Discharging current unbalance” error, the battery module discharging contactor opens. 310 310 311 -=== High contactortemperature===288 +=== Critical error === 312 312 313 - The BMS Main X device protects powercontactors fromoverheating.To measurethe temperatureofthe contactor,oneofthe thermistorsconnectedtotheX5 connectorisused.290 +Parameters for generating the critical error are configured in the "Protections - Critical error" section: 314 314 315 - To changethe overheatingprotectionparameters of power contactors, selectthe"Protections → High contactortemperature"section:292 +[[image:1734356802719-477.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="69" width="600"]] 316 316 317 -[[image:1740756362809-292.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="161" width="800"]] 318 - 319 319 In this section: 320 320 321 -* Enable – a flag to enable the protection; 322 -* Thermistor – a selection of which cell thermistor will be used as contactor temperature sensor; 323 -* Maximum contactor temperature, °C; 324 -* Tolerant contactor temperature, °C; 325 -* Delay before setting the error, second; 326 -* Delay before clearing the error, second; 296 +* Enable – a flag to enable the protection; 297 +* Delay before setting the error; 298 +* Delay before clearing the error; 327 327 * Lock – a flag to block the error until the device is restarted. 328 328 329 - If there isa contactoroverheat,the"Highcontactortemperature" errorisgenerated.301 +The critical error flag is generated if at least one of the following errors persists during the "Delay before setting the error" time: 330 330 331 -Error generation conditions: 303 +* «Battery cover»; 304 +* «Insulation fault»; 305 +* «CH contactor feedback error»; 306 +* «DCH contactor feedback error»; 307 +* «CH/DCH contactor feedback error»; 308 +* «Module offline». 332 332 333 - * the contactortemperatureisgreaterthanthe“Maximumcontactortemperature”value during the“Delay beforesetting the error”time.310 +The critical error flag is cleared if there are no errors from the list above during the "Delay before clearing the error" time. 334 334 335 -Conditions for removing the error: 336 - 337 -* the contactor temperature is lower than the “Tolerant contactor temperature” value during the “Delay before clearing the error” time. 338 - 339 -=== WDT reset === 340 - 341 -If the BMS firmware hangs, the watchdog timer resets the device. The BMS can detect that the device was reset and generates the “WDT reset” error. 342 - 343 -To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 344 - 345 -[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244845-157.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]] 346 - 347 -In this section: 348 - 349 -* Enable – a flag to enable the protection; 350 -* Delay before clearing the error, second; 351 -* Lock – a flag to block the error until the device is restarted. 352 - 353 -Conditions for removing the error: 354 - 355 -* the “Delay before clearing the error” time has passed from the device startup. 356 - 357 357 (% class="box warningmessage" %) 358 358 ((( 359 - If thereisthe"WDTreset" error, **“Critical error”isgenerated.**314 +**When the critical error flag is present, all battery contactors open.** 360 360 ))) 361 - 362 -=== Critical error === 363 - 364 -Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault. 365 - 366 -To change the critical error parameters, select the "Protections → Critical error" section: 367 - 368 -[[image:1740756532131-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]] 369 - 370 -In this section: 371 - 372 -* Enable – a flag to enable the protection; 373 -* Delay before setting the error; 374 -* Delay before clearing the error; 375 -* Lock – a flag to block the error until the device is restarted. 376 - 377 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 378 - 379 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
- 1740756362809-292.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.4 KB - Content
- 1740756532131-419.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.7 KB - Content