... ... @@ -168,11 +168,11 @@
168 168  
169 169  Error generation conditions:
170 170  
171 -* more than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main X device within “Delay before setting the error” time.
171 +* more than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main 3X device within “Delay before setting the error” time.
172 172  
173 173  Conditions for removing the error:
174 174  
175 -* less than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main X device within “Delay before clearing the error” time.
175 +* less than “Number of offline modules to set the error” battery modules do not respond to the commands of the BMS Main 3X device within “Delay before clearing the error” time.
176 176  
177 177  (% class="box warningmessage" %)
178 178  (((
... ... @@ -209,8 +209,6 @@
209 209  * battery module is in the largest group of balanced modules during the "Delay before clearing the error" time;
210 210  * module is ready to charge or discharge.
211 211  
212 -If there is the “Voltage unbalance (CH)” or "Voltage unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**.
213 -
214 214  === Current unbalance (in “Balancing” state) ===
215 215  
216 216  When battery modules are connected in parallel, the most charged modules transfer charge to the least charged modules. The process of charge transfer is accompanied by the flow of balancing currents. The BMS Main X device detects modules with high balancing currents and generates “Current unbalance (CH)” (charge circuit) and “Current unbalance (DCH)” (discharge circuit) errors for them.
... ... @@ -339,31 +339,12 @@
339 339  
340 340  To change the parameters of the watchdog protection, select the "Protections → WDT reset" section:
341 341  
342 -[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244845-157.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]]
343 -
344 -In this section:
345 -
346 -* Enable – a flag to enable the protection;
347 -* Delay before clearing the error, second;
348 -* Lock – a flag to block the error until the device is restarted.
349 -
350 -Conditions for removing the error:
351 -
352 -* the “Delay before clearing the error” time has passed from the device startup.
353 -
354 -(% class="box warningmessage" %)
355 -(((
356 -If there is the "WDT reset" error, **“Critical error” is generated.**
357 -)))
358 -
359 359  === Critical error ===
360 360  
361 -Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
342 +Parameters for generating the critical error are configured in the "Protections - Critical error" section:
362 362  
363 -To change the critical error parameters, select the "Protections → Critical error" section:
344 +[[image:1734356802719-477.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="69" width="600"]]
364 364  
365 -[[image:1740756532131-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]]
366 -
367 367  In this section:
368 368  
369 369  * Enable – a flag to enable the protection;
... ... @@ -371,6 +371,18 @@
371 371  * Delay before clearing the error;
372 372  * Lock – a flag to block the error until the device is restarted.
373 373  
374 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the Delay before setting the error time.
353 +The critical error flag is generated if at least one of the following errors persists during the "Delay before setting the error" time:
375 375  
376 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
355 +* «Battery cover»;
356 +* «Insulation fault»;
357 +* «CH contactor feedback error»;
358 +* «DCH contactor feedback error»;
359 +* «CH/DCH contactor feedback error»;
360 +* «Module offline».
361 +
362 +The critical error flag is cleared if there are no errors from the list above during the "Delay before clearing the error" time.
363 +
364 +(% class="box warningmessage" %)
365 +(((
366 +**When the critical error flag is present, all battery contactors open.**
367 +)))