Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -185,16 +185,14 @@ 185 185 186 186 Protection against voltage unbalance of battery modules is configured in the section "Protections - Voltage unbalance (in any state)": 187 187 188 -[[image:174 0754732291-420.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]188 +[[image:1734356793449-249.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] 189 189 190 190 In this section: 191 191 192 192 * Enable – a flag to enable the protection; 193 193 * Delta voltage – maximum allowable voltage difference of battery modules, V; 194 -* Use the open circuit voltage to detect the error – a flag to enable U,,ocv,, correction; 195 195 * Delay before setting the error; 196 196 * Delay before clearing the error; 197 -* Set the 'Voltage unbalance' error for the modules that are not ready to charge/discharge; 198 198 * Lock – a flag to block the error until the device is restarted. 199 199 200 200 As a result of the operation of the voltage unbalance protection the errors “Voltage unbalance (CH)” and “Voltage unbalance (DCH)” are generated. ... ... @@ -201,16 +201,12 @@ 201 201 202 202 Conditions for generating the error: 203 203 204 -* battery module is not included in the largest group of modules whose voltages differ from each other by no more than "Delta voltage" during the "Delay before setting the error" time; 205 -* module is not ready to charge or discharge; 202 +* battery module is not included in the largest group of modules whose voltages differ from each other by no more than "Delta voltage" during the "Delay before setting the error" time. 206 206 207 207 Conditions for clearing the error: 208 208 209 -* battery module is in the largest group of balanced modules during the "Delay before clearing the error" time; 210 -* module is ready to charge or discharge. 206 +* battery module is in the largest group of balanced modules during the "Delay before clearing the error" time. 211 211 212 -If there is the “Voltage unbalance (CH)” or "Voltage unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**. 213 - 214 214 === Current unbalance (in “Balancing” state) === 215 215 216 216 When battery modules are connected in parallel, the most charged modules transfer charge to the least charged modules. The process of charge transfer is accompanied by the flow of balancing currents. The BMS Main X device detects modules with high balancing currents and generates “Current unbalance (CH)” (charge circuit) and “Current unbalance (DCH)” (discharge circuit) errors for them. ... ... @@ -217,7 +217,7 @@ 217 217 218 218 Protection against current unbalance of battery modules is configured in the section "Protections - Current unbalance": 219 219 220 -[[image: Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244843-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]]214 +[[image:1734356793451-440.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]] 221 221 222 222 In this section: 223 223 ... ... @@ -225,25 +225,19 @@ 225 225 * Maximum current – a maximum allowable self-balancing current of battery modules, A; 226 226 * Delay before setting the error; 227 227 * Delay before clearing the error; 228 -* Check all the time (not only in the ‘Balancing’ state) – a flag to enable voltage check not only in “Balancing” state; 229 229 * Lock – a flag to block the error until the device is restarted. 230 230 231 -As a result of the operation of the current unbalance protection the errors “Current unbalance (CH)” and “Current unbalance (DCH)” are generated. 224 +As a result of the operation of the current unbalance protection the errors “Current unbalance (CH)” and “Current unbalance (DCH)” are generated. Conditions for generating the error: 232 232 233 - Conditionsfor generating the error:226 +* current of the battery module is greater than the "Maximum current" value during the "Delay before setting the error" time. 234 234 235 -* the current of the battery module is greater than the "Maximum current" value during the "Delay before setting the error" time. 236 - 237 237 Conditions for clearing the error: 238 238 239 -* thecurrent of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time.230 +* current of the battery module is less than the "Maximum current" value during the "Delay before clearing the error" time. 240 240 241 -(% class="box infomessage" %) 242 -((( 243 -If there is the “Current unbalance (CH)” or "Current unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**. 244 -))) 232 +If there is the error "Current unbalance (CH)" ("Current unbalance (DCH)"), the charging (discharging) contactor of the battery module opens. 245 245 246 -=== Charging current unbalance (in “Charging” state)===234 +=== Charging current unbalance === 247 247 248 248 During battery charging, the currents of the battery modules may vary. The BMS Main X device detects modules whose charging currents are significantly different from the currents of other modules and generates the “Charging current unbalance” errors for them. 249 249 ... ... @@ -259,10 +259,8 @@ 259 259 * Delay before clearing the error; 260 260 * Lock – a flag to block the error until the device is restarted. 261 261 262 -As a result of the operation of the protection the “Charging current unbalance” are generated. 250 +As a result of the operation of the protection the “Charging current unbalance” are generated. Conditions for generating the errors: 263 263 264 -Conditions for generating the errors: 265 - 266 266 * battery module is not included in the largest group of modules whose charge currents differ from each other by no more than "Delta current" during the "Delay before setting the error" time. 267 267 268 268 Conditions for clearing the error: ... ... @@ -269,10 +269,7 @@ 269 269 270 270 * battery module is included in the largest group of modules with similar charge currents during the “Delay before clearing the error” time. 271 271 272 -(% class="box infomessage" %) 273 -((( 274 -If there is the “Charging current unbalance” error, **corresponding battery module opens its charging contactor**. 275 -))) 258 +If there is the “Charging current unbalance” error, the battery module charging contactor opens. 276 276 277 277 === Discharging current unbalance === 278 278 ... ... @@ -290,10 +290,8 @@ 290 290 * Delay before clearing the error; 291 291 * Lock – a flag to block the error until the device is restarted. 292 292 293 -As a result of the operation of the protection the “Discharging current unbalance” are generated. 276 +As a result of the operation of the protection the “Discharging current unbalance” are generated. Conditions for generating the errors: 294 294 295 -Conditions for generating the errors: 296 - 297 297 * battery module is not included in the largest group of modules whose discharge currents differ from each other by no more than "Delta current" during the "Delay before setting the error" time. 298 298 299 299 Conditions for clearing the error: ... ... @@ -300,77 +300,33 @@ 300 300 301 301 * battery module is included in the largest group of modules with similar discharge currents during the “Delay before clearing the error” time. 302 302 303 -(% class="box infomessage" %) 304 -((( 305 -If there is the “Discharging current unbalance” error, **corresponding battery module opens its discharging contactor**. 306 -))) 284 +If there is the “Discharging current unbalance” error, the battery module discharging contactor opens. 307 307 308 -=== High contactortemperature===286 +=== Critical error === 309 309 310 - The BMS Main X device protects powercontactors fromoverheating.To measurethe temperatureofthe contactor,oneofthe thermistorsconnectedtotheX5 connectorisused.288 +Parameters for generating the critical error are configured in the "Protections - Critical error" section: 311 311 312 - To changethe overheatingprotectionparameters of power contactors, selectthe"Protections → High contactortemperature"section:290 +[[image:1734356802719-477.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="69" width="600"]] 313 313 314 -[[image:1740756362809-292.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="161" width="800"]] 315 - 316 316 In this section: 317 317 318 -* Enable – a flag to enable the protection; 319 -* Thermistor – a selection of which cell thermistor will be used as contactor temperature sensor; 320 -* Maximum contactor temperature, °C; 321 -* Tolerant contactor temperature, °C; 322 -* Delay before setting the error, second; 323 -* Delay before clearing the error, second; 294 +* Enable – a flag to enable the protection; 295 +* Delay before setting the error; 296 +* Delay before clearing the error; 324 324 * Lock – a flag to block the error until the device is restarted. 325 325 326 - If there isa contactoroverheat,the"Highcontactortemperature" errorisgenerated.299 +The critical error flag is generated if at least one of the following errors persists during the "Delay before setting the error" time: 327 327 328 -Error generation conditions: 301 +* «Battery cover»; 302 +* «Insulation fault»; 303 +* «CH contactor feedback error»; 304 +* «DCH contactor feedback error»; 305 +* «CH/DCH contactor feedback error»; 306 +* «Module offline». 329 329 330 - * the contactortemperatureisgreaterthanthe“Maximumcontactortemperature”value during the“Delay beforesetting the error”time.308 +The critical error flag is cleared if there are no errors from the list above during the "Delay before clearing the error" time. 331 331 332 -Conditions for removing the error: 333 - 334 -* the contactor temperature is lower than the “Tolerant contactor temperature” value during the “Delay before clearing the error” time. 335 - 336 -=== WDT reset === 337 - 338 -If the BMS firmware hangs, the watchdog timer resets the device. The BMS can detect that the device was reset and generates the “WDT reset” error. 339 - 340 -To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 341 - 342 -[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244845-157.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]] 343 - 344 -In this section: 345 - 346 -* Enable – a flag to enable the protection; 347 -* Delay before clearing the error, second; 348 -* Lock – a flag to block the error until the device is restarted. 349 - 350 -Conditions for removing the error: 351 - 352 -* the “Delay before clearing the error” time has passed from the device startup. 353 - 354 354 (% class="box warningmessage" %) 355 355 ((( 356 - If thereisthe"WDTreset" error, **“Critical error”isgenerated.**312 +**When the critical error flag is present, all battery contactors open.** 357 357 ))) 358 - 359 -=== Critical error === 360 - 361 -Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault. 362 - 363 -To change the critical error parameters, select the "Protections → Critical error" section: 364 - 365 -[[image:1740756532131-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]] 366 - 367 -In this section: 368 - 369 -* Enable – a flag to enable the protection; 370 -* Delay before setting the error; 371 -* Delay before clearing the error; 372 -* Lock – a flag to block the error until the device is restarted. 373 - 374 -The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 375 - 376 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
- 1740756362809-292.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.4 KB - Content
- 1740756532131-419.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.7 KB - Content