Changes for page 3.4 Protections

Last modified by Admin on 2025/06/11 15:57

From version 15.1
edited by Admin
on 2025/02/28 15:43
Change comment: There is no comment for this version
To version 12.1
edited by Admin
on 2025/02/28 15:28
Change comment: Загрузить новое вложение 1740756532131-419.png

Summary

Details

Page properties
Content
... ... @@ -209,8 +209,6 @@
209 209  * battery module is in the largest group of balanced modules during the "Delay before clearing the error" time;
210 210  * module is ready to charge or discharge.
211 211  
212 -If there is the “Voltage unbalance (CH)” or "Voltage unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**.
213 -
214 214  === Current unbalance (in “Balancing” state) ===
215 215  
216 216  When battery modules are connected in parallel, the most charged modules transfer charge to the least charged modules. The process of charge transfer is accompanied by the flow of balancing currents. The BMS Main X device detects modules with high balancing currents and generates “Current unbalance (CH)” (charge circuit) and “Current unbalance (DCH)” (discharge circuit) errors for them.
... ... @@ -339,23 +339,6 @@
339 339  
340 340  To change the parameters of the watchdog protection, select the "Protections → WDT reset" section:
341 341  
342 -[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244845-157.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]]
343 -
344 -In this section:
345 -
346 -* Enable – a flag to enable the protection;
347 -* Delay before clearing the error, second;
348 -* Lock – a flag to block the error until the device is restarted.
349 -
350 -Conditions for removing the error:
351 -
352 -* the “Delay before clearing the error” time has passed from the device startup.
353 -
354 -(% class="box warningmessage" %)
355 -(((
356 -If there is the "WDT reset" error, **“Critical error” is generated.**
357 -)))
358 -
359 359  === Critical error ===
360 360  
361 361  Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault.
... ... @@ -362,7 +362,7 @@
362 362  
363 363  To change the critical error parameters, select the "Protections → Critical error" section:
364 364  
365 -[[image:1740756532131-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]]
346 +[[image:1734356802719-477.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="69" width="600"]]
366 366  