Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -209,8 +209,6 @@ 209 209 * battery module is in the largest group of balanced modules during the "Delay before clearing the error" time; 210 210 * module is ready to charge or discharge. 211 211 212 -If there is the “Voltage unbalance (CH)” or "Voltage unbalance (DCH)" error, **corresponding battery module opens its charging or discharging contactor**. 213 - 214 214 === Current unbalance (in “Balancing” state) === 215 215 216 216 When battery modules are connected in parallel, the most charged modules transfer charge to the least charged modules. The process of charge transfer is accompanied by the flow of balancing currents. The BMS Main X device detects modules with high balancing currents and generates “Current unbalance (CH)” (charge circuit) and “Current unbalance (DCH)” (discharge circuit) errors for them. ... ... @@ -339,31 +339,12 @@ 339 339 340 340 To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 341 341 342 -[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244845-157.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]] 343 - 344 -In this section: 345 - 346 -* Enable – a flag to enable the protection; 347 -* Delay before clearing the error, second; 348 -* Lock – a flag to block the error until the device is restarted. 349 - 350 -Conditions for removing the error: 351 - 352 -* the “Delay before clearing the error” time has passed from the device startup. 353 - 354 -(% class="box warningmessage" %) 355 -((( 356 -If there is the "WDT reset" error, **“Critical error” is generated.** 357 -))) 358 - 359 359 === Critical error === 360 360 361 - Someoftheerrorsaresystemcritical.A separatesignalnamed"Critical error"indicates a BMS fault.342 +Parameters for generating the critical error are configured in the "Protections - Critical error" section: 362 362 363 - To changehe criticalrror parameters, selectthe"Protections → Criticalor"section:344 +[[image:1734356802719-477.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="69" width="600"]] 364 364 365 -[[image:1740756532131-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]] 366 - 367 367 In this section: 368 368 369 369 * Enable – a flag to enable the protection; ... ... @@ -371,6 +371,18 @@ 371 371 * Delay before clearing the error; 372 372 * Lock – a flag to block the error until the device is restarted. 373 373 374 -The "Critical error"signal is generated if at least one of thecritical errors (see [[Errors>>doc:Battery management systems.Additionalinformation.2\. Stringscontrollers\: signals and errors.WebHome||anchor="HErrors"]])isgeneratedduring the“Delay before setting the error”time.353 +The critical error flag is generated if at least one of the following errors persists during the "Delay before setting the error" time: 375 375 376 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 355 +* «Battery cover»; 356 +* «Insulation fault»; 357 +* «CH contactor feedback error»; 358 +* «DCH contactor feedback error»; 359 +* «CH/DCH contactor feedback error»; 360 +* «Module offline». 361 + 362 +The critical error flag is cleared if there are no errors from the list above during the "Delay before clearing the error" time. 363 + 364 +(% class="box warningmessage" %) 365 +((( 366 +**When the critical error flag is present, all battery contactors open.** 367 +)))
- 1740756532131-419.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.7 KB - Content