Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -337,28 +337,12 @@ 337 337 338 338 To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 339 339 340 -[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244845-157.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]] 341 - 342 -In this section: 343 - 344 -* Enable – a flag to enable the protection; 345 -* Delay before clearing the error, second; 346 -* Lock – a flag to block the error until the device is restarted. 347 - 348 -Conditions for removing the error: 349 - 350 -* the “Delay before clearing the error” time has passed from the device startup. 351 - 352 -If there is the "WDT reset" error, **“Critical error” is generated.** 353 - 354 354 === Critical error === 355 355 356 - Someoftheerrorsaresystemcritical.A separatesignalnamed"Critical error"indicates a BMS fault.342 +Parameters for generating the critical error are configured in the "Protections - Critical error" section: 357 357 358 - To changehe criticalrror parameters, selectthe"Protections → Criticalor"section:344 +[[image:1734356802719-477.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="69" width="600"]] 359 359 360 -[[image:1740756532131-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]] 361 - 362 362 In this section: 363 363 364 364 * Enable – a flag to enable the protection; ... ... @@ -366,6 +366,18 @@ 366 366 * Delay before clearing the error; 367 367 * Lock – a flag to block the error until the device is restarted. 368 368 369 -The "Critical error"signal is generated if at least one of thecritical errors (see [[Errors>>doc:Battery management systems.Additionalinformation.2\. Stringscontrollers\: signals and errors.WebHome||anchor="HErrors"]])isgeneratedduring the“Delay before setting the error”time.353 +The critical error flag is generated if at least one of the following errors persists during the "Delay before setting the error" time: 370 370 371 -The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time. 355 +* «Battery cover»; 356 +* «Insulation fault»; 357 +* «CH contactor feedback error»; 358 +* «DCH contactor feedback error»; 359 +* «CH/DCH contactor feedback error»; 360 +* «Module offline». 361 + 362 +The critical error flag is cleared if there are no errors from the list above during the "Delay before clearing the error" time. 363 + 364 +(% class="box warningmessage" %) 365 +((( 366 +**When the critical error flag is present, all battery contactors open.** 367 +)))
- 1740756532131-419.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.7 KB - Content