Changes for page 3.4 Protections
Last modified by Admin on 2025/06/11 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -337,12 +337,31 @@ 337 337 338 338 To change the parameters of the watchdog protection, select the "Protections → WDT reset" section: 339 339 340 +[[image:Battery management systems.BMS Main 3X.3\. Configuration.3\.4 Protections.WebHome@1734090244845-157.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]] 341 + 342 +In this section: 343 + 344 +* Enable – a flag to enable the protection; 345 +* Delay before clearing the error, second; 346 +* Lock – a flag to block the error until the device is restarted. 347 + 348 +Conditions for removing the error: 349 + 350 +* the “Delay before clearing the error” time has passed from the device startup. 351 + 352 +(% class="box warningmessage" %) 353 +((( 354 +If there is the "WDT reset" error, **“Critical error” is generated.** 355 +))) 356 + 340 340 === Critical error === 341 341 342 - Parametersforgeneratingthe criticalerrorareconfigured inthe "Protections -Critical error"section:359 +Some of the errors are system critical. A separate signal named "Critical error" indicates a BMS fault. 343 343 344 - [[image:1734356802719-477.png||data-xwiki-image-style-alignment="center"data-xwiki-image-style-border="true"height="69" width="600"]]361 +To change the critical error parameters, select the "Protections → Critical error" section: 345 345 363 +[[image:1740756532131-419.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="800"]] 364 + 346 346 In this section: 347 347 348 348 * Enable – a flag to enable the protection; ... ... @@ -350,18 +350,6 @@ 350 350 * Delay before clearing the error; 351 351 * Lock – a flag to block the error until the device is restarted. 352 352 353 -The critical errorflag is generated if at least one of thefollowing errorspersistsduring the"Delay before setting the error"time:372 +The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time. 354 354 355 -* «Battery cover»; 356 -* «Insulation fault»; 357 -* «CH contactor feedback error»; 358 -* «DCH contactor feedback error»; 359 -* «CH/DCH contactor feedback error»; 360 -* «Module offline». 361 - 362 -The critical error flag is cleared if there are no errors from the list above during the "Delay before clearing the error" time. 363 - 364 -(% class="box warningmessage" %) 365 -((( 366 -**When the critical error flag is present, all battery contactors open.** 367 -))) 374 +The “Critical error" signal is cleared if there are no errors from the list above during the “Delay before clearing the error” time.
- 1740756532131-419.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.7 KB - Content