Changes for page 3.3 Control

Last modified by Admin on 2025/06/11 15:52

From version 8.2
edited by Admin
on 2025/02/28 13:37
Change comment: There is no comment for this version
To version 5.1
edited by Admin
on 2025/02/28 13:32
Change comment: Загрузить новое вложение 1740749535746-215.png

Summary

Details

Page properties
Content
... ... @@ -8,7 +8,7 @@
8 8  
9 9  General parameters of BMS Main X are configured in the «Control → General» section:
10 10  
11 -[[image:1740747822632-731.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="111" width="800"]]
11 +[[image:1740747822632-731.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="600"]]
12 12  
13 13  In this section:
14 14  
... ... @@ -20,16 +20,14 @@
20 20  
21 21  Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section:
22 22  
23 -[[image:1740747928147-952.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="226" width="800"]]
23 +[[image:1740747928147-952.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="170" width="600"]]
24 24  
25 25  The network addresses of the battery modules are configured in the "Control - Modules - Node IDs" section:
26 26  
27 -[[image:1740747965546-449.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="252" width="800"]]
27 +[[image:1740747965546-449.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="189" width="600"]]
28 28  
29 29  Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main or BMS Mini S / BMS Mini 2 settings.
30 30  
31 -In corresponding section you can set up minimum number of found modules to finish initialization.
32 -
33 33  === Calculation of battery parameters ===
34 34  
35 35  The BMS Main X device calculates battery parameters based on user settings.
... ... @@ -36,73 +36,13 @@
36 36  
37 37  Calculation of the battery state of charge (SOC) is configured in the "Control - Calculation - Final SOC" section:
38 38  
39 -[[image:1740749535746-215.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]]
37 +[[image:1734356553572-909.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="81" width="600"]]
40 40  
41 41  The following battery SOC calculation methods are supported:
42 42  
43 -* Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules;
44 -* Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules;
45 -* Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the modules. Final SOC will be a) 100% if any module has 100% SOC, b) 0% if any module has 0% SOC;
46 -* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the modules. Final SOC will be a) 100% if all modules have 100% SOC, b) 0% if all modules have 0% SOC;
41 +* Minimum SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules;
42 +* Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules.
47 47  
48 -Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported:
49 -
50 -* Minimal SOH – SOH of the modular battery is assumed to be the minimum SOH among the battery modules;
51 -* Average SOH – SOH of the modular battery is taken equal to the arithmetic average of the SOH of the battery modules.
52 -
53 -=== Main contactor ===
54 -
55 -The BMS Main X device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors.
56 -
57 -The Main contactor algorithm supports the following modes:
58 -
59 -* Always on;
60 -* Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging, Discharging and Charging/Discharging contactors.
61 -
62 -In “Always on” mode main contactor closes if all the following is true:
63 -
64 -* Other contactors are open;
65 -* There are no errors from the "Errors 1, 2 ..." bitfileds.
66 -
67 -In “Always on” mode main contactor opens if all the following is true:
68 -
69 -* Other contactors are open;
70 -* There is an error from the the "Errors 1, 2 ..." bitfileds.
71 -
72 -In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.
73 -
74 -To change the parameters of the main contactor, select the "Control → Main contactor" section:
75 -
76 -[[image:1740749605680-464.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="800"]]
77 -
78 -In this section:
79 -
80 -* Enable – a flag to enable the main contactor control;
81 -* Algorithm – main contactor control algorithm:
82 -** Always on – contactor is always closed;
83 -** Automatic – contactor closes by internal charge and discharge algorithms;
84 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed, millisecond;
85 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, millisecond;
86 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset;
87 -* Errors to open the main contactor – error flags that cause the contactor to open.
88 -
89 -=== Charging status ===
90 -
91 -To change the parameters for generating status signals when charging the battery, select the section “Control → Charging status”:
92 -
93 -[[image:1740749824773-539.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="104" width="800"]]
94 -
95 -In this section:
96 -
97 -* Current corresponding to charging – a current level to set the "Charging current present" signal, A;
98 -* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A.
99 -
100 -=== Discharging status ===
101 -
102 -To change the parameters for generating status signals when discharging the battery, select the section “Control → Discharging status”:
103 -
104 -[[image:1740749862820-455.png]]
105 -
106 106  === Charge ===
107 107  
108 108  The BMS Main X device manages the parallel connection of the battery modules and the connection of the battery to the charging circuit.
1740749605680-464.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -21.5 KB
Content
1740749824773-539.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -16.4 KB
Content
1740749862820-455.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -15.2 KB
Content