Changes for page 3.3 Control

Last modified by Admin on 2025/06/11 15:52

From version 8.1
edited by Admin
on 2025/02/28 13:37
Change comment: Загрузить новое вложение 1740749862820-455.png
To version 8.2
edited by Admin
on 2025/02/28 13:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -73,8 +73,36 @@
73 73  
74 74  To change the parameters of the main contactor, select the "Control → Main contactor" section:
75 75  
76 -[[image:1740749605680-464.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="88" width="600"]]
76 +[[image:1740749605680-464.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="800"]]
77 77  
78 +In this section:
79 +
80 +* Enable – a flag to enable the main contactor control;
81 +* Algorithm – main contactor control algorithm:
82 +** Always on – contactor is always closed;
83 +** Automatic – contactor closes by internal charge and discharge algorithms;
84 +* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed, millisecond;
85 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, millisecond;
86 +* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset;
87 +* Errors to open the main contactor – error flags that cause the contactor to open.
88 +
89 +=== Charging status ===
90 +
91 +To change the parameters for generating status signals when charging the battery, select the section “Control → Charging status”:
92 +
93 +[[image:1740749824773-539.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="104" width="800"]]
94 +
95 +In this section:
96 +
97 +* Current corresponding to charging – a current level to set the "Charging current present" signal, A;
98 +* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A.
99 +
100 +=== Discharging status ===
101 +
102 +To change the parameters for generating status signals when discharging the battery, select the section “Control → Discharging status”:
103 +
104 +[[image:1740749862820-455.png]]
105 +
78 78  === Charge ===
79 79  
80 80  The BMS Main X device manages the parallel connection of the battery modules and the connection of the battery to the charging circuit.